Experimental study on hysteretic characteristics of shear thickening fluid dampers with energy storage devices
Smart Materials and Structures · 01.04.2026 · 35 (4) · 045032
DOI: 10.1088/1361-665x/ae5b01 ↗Kurz gefasst
Fachartikel in der Zeitschrift Smart Materials and Structures, online erschienen am 15.04.2026. Verfasst von Gangwei Mei und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben.
Abstract (Originalsprache)
Carbon nanotube modified shear thickening fluid (CNT-STF) is an advanced composite material that holds enormous potential for impact and vibration control. However, existing research mostly focuses on its rheological properties after modification, with no systematic studies on energy-storage-integrated damper structures capable of effectively exploiting its tension–compression mechanical asymmetry. This paper proposes a novel CNT-STF damper integrated with an energy storage device, focusing on its unique tension–compression mechanical asymmetry. The damper combines the energy storage device with the CNT-STF matrix, leveraging the excellent rheological properties of CNT-STF while highlighting its core advantage of mechanical asymmetry, thereby providing reliable directional energy dissipation and flexible buffering performance. Based on its rheological and structural characteristics, this study adopts a combination of material preparation, characterization, and dynamic testing to explore the damper’s dynamic mechanical response and verify its performance advantages: first characterizing the rheological properties of CNT-STF, followed by scanning electron microscope observation to reveal the microstructural basis of its mechanical properties, and ultimately employing the MTS793 system to validate the damper’s effectiveness. The results demonstrate that the damper achieves stable viscoelastic energy dissipation at low frequencies and fully triggers the shear thickening effect at medium and high frequencies; under the working condition of 5.0 Hz and 10 mm amplitude, it exhibits a maximum tensile damping force of 2.51 kN, a compressive damping force of 2.1 kN, a hysteresis area tension–compression ratio of 2.6, and a controllability coefficient K = 4.02, outperforming both traditional dampers and pure STF dampers. Finally, combined with the test and observation results, the formation mechanism and dynamic response law of its mechanical asymmetry are clarified, providing guidance for the application of CNT-STF and the design of high-performance asymmetric dampers.
Zitieren
APA
Mei, G., Dai, M., Li, C., He, Y., Yao, X., Shen, J., & Wang, Y. (2026). Experimental study on hysteretic characteristics of shear thickening fluid dampers with energy storage devices. Smart Materials and Structures, 35(4), 045032. https://doi.org/10.1088/1361-665x/ae5b01
Vancouver
Mei G, Dai M, Li C, He Y, Yao X, Shen J, et al. Experimental study on hysteretic characteristics of shear thickening fluid dampers with energy storage devices. Smart Materials and Structures. 2026;35(4):045032. doi:10.1088/1361-665x/ae5b01
BibTeX
@article{Mei2026,
author = {Mei, Gangwei and Dai, Mengnan and Li, Chunhai and He, Yongsheng and Yao, Xiongliang and Shen, Jun and Wang, Yunqiang},
title = {Experimental study on hysteretic characteristics of shear thickening fluid dampers with energy storage devices},
journal = {Smart Materials and Structures},
year = {2026},
volume = {35},
number = {4},
pages = {045032},
doi = {10.1088/1361-665x/ae5b01}
}