Collisional-radiative diagnostics of laser-produced cadmium plasma
Plasma Sources Science and Technology · 01.08.2026 · 35 (8) · 085012
DOI: 10.1088/1361-6595/ae8dfe ↗Kurz gefasst
Fachartikel in der Zeitschrift Plasma Sources Science and Technology, online erschienen am 11.08.2026. Verfasst von Nitish Ghosh und 1 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben.
Abstract (Originalsprache)
A comprehensive collisional radiative model is developed for the diagnostics of laser-produced cadmium plasma. In such low-temperature plasmas, electron-impact excitation processes play a dominant role. However, reliable and comprehensive excitation cross-section data for Cd atom are scarce in the literature, limiting the construction of reliable plasma models. To address this limitation, electron-impact excitation cross-sections for a large number of fine-structure transitions of Cd I are calculated using the relativistic distorted wave approximation. The required atomic structure data, including excitation energies and radiative transition probabilities, are obtained using the multi-configuration Dirac–Hartree–Fock approach and validated against the NIST database. The calculated excitation cross sections, in addition to electron-impact de-excitation, radiative decay processes, electron-impact ionization, and three-body recombination, are integrated into the collisional-radiative (CR) model, which comprises 56 fine-structure levels of Cd I and the ground level of Cd II. The resulting particle balance equations are solved over a large grid of electron temperatures and electron densities to obtain level populations and emission line intensities. Plasma diagnostics performed using laser-induced breakdown spectroscopy measurements conducted by Bredice et al (2013 Braz. J. Phys. 43 239–246). By employing a minimum scatter technique to compare normalized theoretical and experimental intensities, the electron temperature and electron density of the plasma are extracted. The present study establishes a reliable CR modeling framework for cadmium plasma diagnostics and demonstrates its applicability under non-equilibrium, low-temperature plasma conditions.
Zitieren
APA
Ghosh, N., & Sharma, L. (2026). Collisional-radiative diagnostics of laser-produced cadmium plasma. Plasma Sources Science and Technology, 35(8), 085012. https://doi.org/10.1088/1361-6595/ae8dfe
Vancouver
Ghosh N, Sharma L. Collisional-radiative diagnostics of laser-produced cadmium plasma. Plasma Sources Science and Technology. 2026;35(8):085012. doi:10.1088/1361-6595/ae8dfe
BibTeX
@article{Ghosh2026,
author = {Ghosh, Nitish and Sharma, Lalita},
title = {Collisional-radiative diagnostics of laser-produced cadmium plasma},
journal = {Plasma Sources Science and Technology},
year = {2026},
volume = {35},
number = {8},
pages = {085012},
doi = {10.1088/1361-6595/ae8dfe}
}
EUVIMED