A microsecond-latency real-time Thomson scattering system on the HL-3 Tokamak
Plasma Physics and Controlled Fusion · 01.05.2026 · 68 (5) · 055021
DOI: 10.1088/1361-6587/ae6a67 ↗Kurz gefasst
Fachartikel in der Zeitschrift Plasma Physics and Controlled Fusion, online erschienen am 19.05.2026. Verfasst von W Y Zhai und 17 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Key R&D Program of China under Grant, Innovation Program of Southwestern Institute of Physics under Grant.
Abstract (Originalsprache)
Real-time (RT) electron temperature ( T e ) diagnostics are fundamental for active profile control in tokamaks. This paper present a field-programmable gate array-based RT Thomson scattering processor deployed on the HL-3 tokamak. Driven by strict RT constraints, the fully pipelined architecture integrates Z -score standardization with a lookup-table inversion. This removes the explicit amplitude degree of freedom in the mapping definition, fundamentally mitigating sensitivity to global signal scaling. The hardware achieves a deterministic trigger-to-output latency of 22.4 μ s . To guarantee RT data reliability for prospective closed-loop control, a firmware-level gating mechanism explicitly flags low-confidence samples, bounded by a Monte Carlo baseline error assessment. Benchmarked against an offline non-linear least-squares reference via a shared-trigger setup, the system demonstrates exceptional agreement across 142 valid pulses, yielding a linear fit of y = 1.00 x − 0.002 ( R > 0.999 ). Validated under 30 Hz single-point operation, this architecture establishes a definitive microsecond-latency foundation for future multi-point RT upgrades.
Förderung
- National Key R&D Program of China under Grant
- Innovation Program of Southwestern Institute of Physics under Grant
Zitieren
APA
Zhai, W. Y., Guo, W. P., Hou, Z. P., Gong, X. W., Xia, F., Gong, S. B., He, Z. C., Liu, C. H., Ren, L. L., Wu, J. B., Long, X. A., Tong, R. H., Li, J. X., Xiao, G. L., Shi, Z. B., Funaba, H., Yamada, I., & Zhong, W. L. (2026). A microsecond-latency real-time Thomson scattering system on the HL-3 Tokamak. Plasma Physics and Controlled Fusion, 68(5), 055021. https://doi.org/10.1088/1361-6587/ae6a67
Vancouver
Zhai WY, Guo WP, Hou ZP, Gong XW, Xia F, Gong SB, et al. A microsecond-latency real-time Thomson scattering system on the HL-3 Tokamak. Plasma Physics and Controlled Fusion. 2026;68(5):055021. doi:10.1088/1361-6587/ae6a67
BibTeX
@article{Zhai2026,
author = {Zhai, W Y and Guo, W P and Hou, Z P and Gong, X W and Xia, F and Gong, S B and He, Z C and Liu, C H and Ren, L L and Wu, J B and Long, X A and Tong, R H and Li, J X and Xiao, G L and Shi, Z B and Funaba, H and Yamada, I and Zhong, W L},
title = {A microsecond-latency real-time Thomson scattering system on the HL-3 Tokamak},
journal = {Plasma Physics and Controlled Fusion},
year = {2026},
volume = {68},
number = {5},
pages = {055021},
doi = {10.1088/1361-6587/ae6a67}
}