EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection

Scott Desai iD, Wei Shi

Physiological Measurement · 11.11.2026

DOI: 10.1088/1361-6579/aec110 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 11.11.2026. Verfasst von Scott Desai und 1 weiteren Autor:innen. Beteiligte Einrichtung: Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, K1S 5B6, Canada. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective: Detecting heartbeats in photoplethysmography (PPG) underlies heart-rate, heart-rate-variability and arrhythmia analysis on wearable and clinical devices, and must be both efficient and accurate. Several accurate benchmark detectors, especially the multi-scale peak-and-trough family (MSPTD/MSPTDfast), rely on costly local-maxima scalograms; we seek a detector that improves the benchmark-wide speed–accuracy trade-off rather than merely accelerating one baseline.

Approach: MorphSSF converts each PPG window to a slope-sum function (SSF), estimates the dominant pulse period from a band-limited autocorrelation, and selects candidates as fixed points of a period-matched running-maximum dilation on the SSF. This combines systolic-upstroke enhancement with adaptive period spacing using one-dimensional operations and no scalogram. We evaluate under identical conditions on seven datasets (544 recordings) with benchmark-wide rank tests, detector-specific exclusions and one-to-one matching. Separate fixed-point C and causal MATLAB variants are evaluated.

Main results: MorphSSF has the best mean dataset F1 rank. Against MSPTDfast (v2), sensitivity tests favour MorphSSF on five datasets (including a zero median effect on CapnoBase); F1 is higher on MIMIC-test, MIMIC-train and PPG-DaLiA, while positive predictive value (PPV) is lower on WESAD. Both pooled and equal-dataset analyses favour MorphSSF in F1 against all eight baselines. MorphSSF is 3.05–218.18× faster than the eight baselines, including 3.23× faster than MSPTDfast (v2), based on median runtime ratios across recordings. All detectors receive the same prefiltered PPG input, with this shared filtering step excluded from runtime measurements.

Significance: Period-adaptive detection on the slope-sum provides an efficient, scalogram-free approach to PPG beat detection.

Schlagwörter

Stichwörter der Autor:innen

beat detectionheart ratemathematical morphologyphotoplethysmographypulse detectionslope-sum functionwearable sensing

Autor:innen und Institutionen

  • Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, K1S 5B6, Canada.

ORCID-Profile: Scott Desai

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Desai, S., & Shi, W. (2026). MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection. Physiological Measurement. https://doi.org/10.1088/1361-6579/aec110

Vancouver

Desai S, Shi W. MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection. Physiological Measurement. 2026. doi:10.1088/1361-6579/aec110

BibTeX
@article{Desai2026,
  author = {Desai, Scott and Shi, Wei},
  title = {MorphSSF: a fast slope-sum adaptive-period dilation algorithm for photoplethysmography beat detection},
  journal = {Physiological Measurement},
  year = {2026},
  doi = {10.1088/1361-6579/aec110}
}
Kostenlos starten →