Patient-referenced and trajectory features from serial ECGs for haemodynamic monitoring: an in silico study with external feasibility analysis
Physiological Measurement · 30.11.2026 · 47 (11) · 115009
DOI: 10.1088/1361-6579/aebde3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 13.11.2026. Verfasst von Yen-Hsiang Wang. Beteiligte Einrichtung: Graduate Institute of Medical Sciences, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan. Hauptthemen laut MEDLINE: Electrocardiography, Computer Simulation, Hemodynamics, Signal Processing, Computer-Assisted. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective. Physiological measurements are read against population thresholds, although the within-person change that signals deterioration is smaller than the spread between people. We asked, in simulation, whether serial electrocardiograms read against a patient’s own earlier recording carry information about haemodynamic state, and whether the trajectory of that change adds to its current value, in acute haemorrhage. Approach. A nine-dimensional circulatory state-space model generated 600 synthetic subjects in whom haemorrhage reached the waveform only through subject-specific couplings. Results were audited against elapsed time and heart rate, repeated under alternative observation models and with an unknown bleeding onset, and examined in an external feasibility analysis of 77 intraoperative recordings. Main results. Under the generative model, a personal reference raised state discrimination from 0.847 to 0.951 but helped event prediction less than the slope and curvature of the change, which raised five-minute decompensation discrimination from 0.876 to 0.953. Elapsed time, patient characteristics and heart rate reached 0.930 without any electrocardiogram; with onset randomised that shortcut disappeared and the waveform still added +0.084. This division of labour held in all 7 observation models and 24 sampled coupling sets. Intraoperatively, patient-referenced features discriminated concurrent hypotension better (0.683) than absolute features or heart rate, but added nothing distinguishable from zero to the recorded anaesthetic and ventilatory state. Significance. Under the stated assumptions, a personal reference estimates where a patient is and its trajectory where they are going. The external cohort provides preliminary evidence for the portability of the patient-referenced representation but is insufficient to establish clinical performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate Institute of Medical Sciences, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
- School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
ORCID-Profile: Yen-Hsiang Wang
Zitieren
APA
Wang, Y. H. (2026). Patient-referenced and trajectory features from serial ECGs for haemodynamic monitoring: an in silico study with external feasibility analysis. Physiological Measurement, 47(11), 115009. https://doi.org/10.1088/1361-6579/aebde3
Vancouver
Wang YH. Patient-referenced and trajectory features from serial ECGs for haemodynamic monitoring: an in silico study with external feasibility analysis. Physiological Measurement. 2026;47(11):115009. doi:10.1088/1361-6579/aebde3
BibTeX
@article{Wang2026,
author = {Wang, Yen-Hsiang},
title = {Patient-referenced and trajectory features from serial ECGs for haemodynamic monitoring: an in silico study with external feasibility analysis},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {11},
pages = {115009},
doi = {10.1088/1361-6579/aebde3}
}
EUVIMED