Correction-stage information leakage and target–input asymmetry can distort comparisons of fNIRS short-separation channel correction strategies
Physiological Measurement · 30.11.2026 · 47 (11) · 115001
DOI: 10.1088/1361-6579/aeb8de ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Physiological Measurement, online erschienen am 03.11.2026. Verfasst von Esra Süzen. Beteiligte Einrichtung: Department of Biomedical Engineering, Faculty of Engineering, Akdeniz University, Dumlupınar Boulevard, Campus, 07058 Konyaaltı, Antalya, Türkiye. Hauptthemen laut MEDLINE: Signal Processing, Computer-Assisted. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective. We examined how evaluation design affects comparisons of functional near-infrared spectroscopy short-separation correction strategies. Approach. Nearest-SC, All-SC, SC-PCA and an adapted tCCA-GLM were compared in a multimodal resting-state dataset ( n = 14), using semi-nested and correction-stage fully nested cross-validation, boundary purging, symmetric leave-one-modality-out (LOMO) evaluation, circular-shift nulls, injected hemodynamic response function recovery and a second cohort. Main results. In the fixed-seed purged joint-target analysis, the adapted tCCA-GLM had a null-adjusted Δ R 2 of −1.1%. Symmetric LOMO, which evaluates reduced tCCA models, yielded no statistically detected method differences (all paired p ⩾ 0.3685), but did not establish equivalence or separately quantify leakage and input–target overlap. Motion-targeted external validation provided partial support for an evaluation-tier × method interaction (Freedman–Lane p < 0.005). SC-PCA had lower mean known-truth normalized root mean square error (nRMSE = 0.037) than the adapted tCCA-GLM (0.121); within-metric Holm-adjusted comparisons were significant for this contrast and for amplitude-bias comparisons with all three SC-based strategies, but not for slopes. Sensitivity analyses included training-fold PCA selection, LOMO boundary/segment-filtering checks, lagged evaluation and longer test blocks. Significance. Benchmarks should fit learned correction stages within training data, disclose correction–evaluation overlap and assess signal preservation separately. Findings are specific to the evaluated implementations, outcomes and datasets.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Faculty of Engineering, Akdeniz University, Dumlupınar Boulevard, Campus, 07058 Konyaaltı, Antalya, Türkiye.
ORCID-Profile: Esra Süzen
Zitieren
APA
Süzen, E. (2026). Correction-stage information leakage and target–input asymmetry can distort comparisons of fNIRS short-separation channel correction strategies. Physiological Measurement, 47(11), 115001. https://doi.org/10.1088/1361-6579/aeb8de
Vancouver
Süzen E. Correction-stage information leakage and target–input asymmetry can distort comparisons of fNIRS short-separation channel correction strategies. Physiological Measurement. 2026;47(11):115001. doi:10.1088/1361-6579/aeb8de
BibTeX
@article{Szen2026,
author = {Süzen, Esra},
title = {Correction-stage information leakage and target–input asymmetry can distort comparisons of fNIRS short-separation channel correction strategies},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {11},
pages = {115001},
doi = {10.1088/1361-6579/aeb8de}
}
EUVIMED