A gated artifact management pipeline for low-density eyewear EEG
Physiological Measurement · 2026
DOI: 10.1088/1361-6579/ae99ab ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, 2026. Verfasst von Andrea Costanzo Palmisciano und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy. Hauptthemen laut MEDLINE: Artifacts, Electroencephalography, Signal Processing, Computer-Assisted, Wearable Electronic Devices. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union NextGenerationEU.
Abstract (Originalsprache)
Objective . To develop an artifact-management method suitable for low-density, dry-electrode electroencephalogram (EEG) recorded from a wearable eyewear platform, enabling artifact detection, classification, and correction while avoiding unnecessary processing of clean neural activity. Approach . A gated two-stage pipeline is proposed in which a lightweight gate classifier first identifies artifact-contaminated EEG windows and selectively triggers further processing only when needed. The complete pipeline combines: (i) a time-domain feature-based detector, (ii) a convolutional–recurrent network for three-class artifact discrimination (eye blinks, horizontal eye movements, facial movements), and (iii) a U-Net-based denoising autoencoder. Main results . Evaluated on the eyewear EEG dataset (29 subjects) using a leave-one-subject-out scheme, the gate classifier achieved a balanced accuracy of 0.89. The artifact classifier reached a balanced accuracy of 0.84 with a median macro-F1 of 0.83. The denoiser achieved a median normalized RMSE lower than 0.20 and a spectral cosine similarity above 0.84. In the end-to-end evaluation, the pipeline achieved a median normalized RMSE of 0.19 and a spectral cosine similarity of 0.89. Evaluation on an independent external benchmark showed that the proposed pipeline maintained a slightly lower gate detection performance (balanced accuracy 0.82) and achieved higher two-class classification performance. The denoising performance was comparable to that obtained on the dataset collected for this study, with absolute median differences not exceeding 0.04 for both normalized RMSE and spectral cosine similarity. Significance . These results support the effectiveness of the proposed approach for artifact management in wearable eyewear EEG, while maintaining a design compatible with resource-constrained wearable implementations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, Italy.
- Smart Eyewear Lab, EssilorLuxottica, Milano, Italy.
- Department of Industrial and Information Engineering, Universitá di Pavia, Pavia, Italy.
ORCID-Profile: Andrea Costanzo Palmisciano, Andrea Farabbi, Francesco Latino, Matteo Rossi, Niccoló Antonello, Pietro Cerveri, Luca Mainardi
Förderung
- European Union NextGenerationEU
Zitieren
APA
Costanzo Palmisciano, A., Farabbi, A., Latino, F., Rossi, M., Antonello, N., Cerveri, P., & Mainardi, L. (2026). A gated artifact management pipeline for low-density eyewear EEG. Physiological Measurement. https://doi.org/10.1088/1361-6579/ae99ab
Vancouver
Costanzo Palmisciano A, Farabbi A, Latino F, Rossi M, Antonello N, Cerveri P, et al. A gated artifact management pipeline for low-density eyewear EEG. Physiological Measurement. 2026. doi:10.1088/1361-6579/ae99ab
BibTeX
@article{CostanzoPalmisciano2026,
author = {Costanzo Palmisciano, Andrea and Farabbi, Andrea and Latino, Francesco and Rossi, Matteo and Antonello, Niccoló and Cerveri, Pietro and Mainardi, Luca},
title = {A gated artifact management pipeline for low-density eyewear EEG},
journal = {Physiological Measurement},
year = {2026},
doi = {10.1088/1361-6579/ae99ab}
}
EUVIMED