Practical optimization of deep learning models for cuffless blood pressure estimation from photoplethysmography
Physiological Measurement · 31.08.2026 · 47 (8) · 085027
DOI: 10.1088/1361-6579/ae944f ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 21.08.2026. Verfasst von Vikas Khurana und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Wright Center for Graduate Medical Education, 501 S Washington Avenue, Scranton, PA, United States of America. Hauptthemen laut MEDLINE: Photoplethysmography, Deep Learning, Blood Pressure Determination, Signal Processing, Computer-Assisted. Die Arbeit nennt 60 Literaturangaben.
Abstract (Originalsprache)
Objective. To improve deep learning–based cuffless blood pressure (BP) estimation from photoplethysmography (PPG) for continuous, non-invasive monitoring when cuff measurements are impractical, by assessing sampling frequency, systolic BP (SBP) and diastolic BP (DBP) derivation, respiratory rate (RR) effects, and errors at BP extremes. Approach. We analysed 205 850 ten-second paired PPG–arterial BP segments from the medical information mart for intensive care waveform database. A convolutional model with a multiresolution U-Net translated PPG to arterial BP waveforms. Inputs at 125, 62.5, and 31.25 Hz were compared. SBP and DBP were derived by minimum–maximum extraction or by averaging the top 4 systolic peaks and bottom 4 diastolic troughs per segment. Performance was summarized using mean absolute error (MAE). Main results. Inputs at 62.5 Hz reduced MAE versus 125 Hz (SBP 5.24 vs 6.34 mmHg; DBP 2.87 vs 3.27 mmHg), whereas 31.25 Hz increased error (SBP 16.09 mmHg; DBP 9.10 mmHg). Multi-peak averaging outperformed minimum–maximum extraction. MAE varied across RRs, with generally lower errors observed at moderate RRs, and higher errors observed at lower and higher SBP ranges. Significance. Sampling frequency, SBP/DBP derivation, and RR shape error patterns in PPG-only cuffless BP estimation, with higher errors at low and high SBP. These results inform device design for bedside and ambulatory monitoring. However, further validation using subject-level datasets is required to assess clinical applicability and compliance with established validation standards.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Wright Center for Graduate Medical Education, 501 S Washington Avenue, Scranton, PA, United States of America.
- Indian School of Business, Gachibowli, Hyderabad, Telangana 500111, India.
- IITK Foundation, 3790 El Camino Real, #1038, Palo Alto, CA 94306, United States of America.
- Temple University, 1810 Liacouras Walk, Room 284b, Philadelphia, PA 19122, United States of America.
- Department of Medicine, Division of Pulmonary, Allergy and Critical Care Medicine, Oregon Health & Sciences University, Portland, OR, United States of America.
ORCID-Profile: Vikas Khurana, Aejaz Mohammad Pamidi, Bharat Bhushan Joshi, Rajesh Reddy Goutha, Akram Khan
Zitieren
APA
Khurana, V., Pamidi, A. M., Joshi, B. B., Belde, G., Goutha, R. R., Bajpai, R., Kumar, S., & Khan, A. (2026). Practical optimization of deep learning models for cuffless blood pressure estimation from photoplethysmography. Physiological Measurement, 47(8), 085027. https://doi.org/10.1088/1361-6579/ae944f
Vancouver
Khurana V, Pamidi AM, Joshi BB, Belde G, Goutha RR, Bajpai R, et al. Practical optimization of deep learning models for cuffless blood pressure estimation from photoplethysmography. Physiological Measurement. 2026;47(8):085027. doi:10.1088/1361-6579/ae944f
BibTeX
@article{Khurana2026,
author = {Khurana, Vikas and Pamidi, Aejaz Mohammad and Joshi, Bharat Bhushan and Belde, Ganesh and Goutha, Rajesh Reddy and Bajpai, Ratan and Kumar, Subodha and Khan, Akram},
title = {Practical optimization of deep learning models for cuffless blood pressure estimation from photoplethysmography},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {8},
pages = {085027},
doi = {10.1088/1361-6579/ae944f}
}
EUVIMED