EUVIMEDEUVIMED entdecken
Crossref

Analysis of the frequency-dependent sensitivity distribution for lower forearm impedance plethysmography

Niko Strotmann iD, Christian Wiede iD, Roman Kusche iD, Karsten Seidl iD

Physiological Measurement · 31.08.2026 · 47 (8) · 085020

DOI: 10.1088/1361-6579/ae9035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 18.08.2026. Verfasst von Niko Strotmann und 3 weiteren Autor:innen. Beteiligte Einrichtung: Fraunhofer IMS, Duisburg, Germany. Hauptthemen laut MEDLINE: Forearm. Die Arbeit nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . The assessment of hemodynamic parameters plays an important role for the diagnosis and detection of cardiovascular diseases. One of the promising techniques for the non-invasive and continuous monitoring of arterial hemodynamics is the impedance plethysmography (IPG), which aims to measure the pulsatile volume change of superficial arteries. Crucial for the success of an IPG measurement is the selection of a setup that effectively targets the artery. Approach . This work analyzes the influence of the injection frequency alteration on the sensitivity distribution of an IPG measurement and the sensitivity towards the radial artery. The analysis is performed both in simulation and using study data obtained from 41 participants. The simulation consists of a finite element model representing the lower forearm and a fixed IPG setup, in which the sensitivity distribution is analyzed for different excitation frequencies between 3 kHz and 100 kHz. To allow for comparison, the IPG study utilizes the same five excitation frequencies between 3 kHz and 100 kHz. Main results . The results of the finite element simulation show that increasing excitation frequency shifts the region of large sensitivity away from the artery and especially towards deeper muscle tissue layers. The analysis of the study data supports this hypothesis by demonstrating that lower-frequency excitation yields larger relative pulsatile changes than larger excitation frequencies, thus indicating a larger sensitivity towards the pulsatile artery. Significance . The results of this paper show, that injection frequency directly affects the sensitivity regions. Analysis of the finite element method and study results indicate that the largest sensitivity towards the radial artery occurs at the smallest injection frequency. Thus, comparison of IPG measurements performed at different excitation frequencies should be interpreted carefully, comparability between individual measurements may be limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ForearmHumansPlethysmography, ImpedanceFinite Element AnalysisMaleFemaleAdult

Stichwörter der Autor:innen

finite element modelingimpedance plethysmographysensitivity analysis

Autor:innen und Institutionen

  • Fraunhofer IMS, Duisburg, Germany.
  • Faculty of Electrical Engineering, Media and Information Technology, Hamburg University of Applied Sciences, Hamburg, Germany.
  • Department of Electronic Components and Circuits, University of Duisburg-Essen, Duisburg, Germany.

ORCID-Profile: Niko Strotmann, Christian Wiede, Roman Kusche, Karsten Seidl

Zitieren

APA

Strotmann, N., Wiede, C., Kusche, R., & Seidl, K. (2026). Analysis of the frequency-dependent sensitivity distribution for lower forearm impedance plethysmography. Physiological Measurement, 47(8), 085020. https://doi.org/10.1088/1361-6579/ae9035

Vancouver

Strotmann N, Wiede C, Kusche R, Seidl K. Analysis of the frequency-dependent sensitivity distribution for lower forearm impedance plethysmography. Physiological Measurement. 2026;47(8):085020. doi:10.1088/1361-6579/ae9035

BibTeX
@article{Strotmann2026,
  author = {Strotmann, Niko and Wiede, Christian and Kusche, Roman and Seidl, Karsten},
  title = {Analysis of the frequency-dependent sensitivity distribution for lower forearm impedance plethysmography},
  journal = {Physiological Measurement},
  year = {2026},
  volume = {47},
  number = {8},
  pages = {085020},
  doi = {10.1088/1361-6579/ae9035}
}
Kostenlos starten →