Continuous fast tracking of auditory threshold during middle ear surgery using the auditory steady state response (ASSR)
Physiological Measurement · 31.08.2026 · 47 (8) · 085005
DOI: 10.1088/1361-6579/ae9032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 05.08.2026. Verfasst von Robert B Patuzzi und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Arthur Emmett Research Institute, Perth, Australia. Hauptthemen laut MEDLINE: Auditory Threshold, Ear, Middle, Evoked Potentials, Auditory, Brain Stem, Otologic Surgical Procedures. Die Arbeit nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective To continuously track auditory threshold during middle ear surgery, using the auditory brainstem response (ABR) as an indirect measure of cochlear sensitivity, thereby providing surgeons with timely feedback to help avoid iatrogenic hearing loss. Approach We improved the signal-to-noise ratio of the electrophysiological measurement of ABRs to repetitive bone-conducted chirps (logarithmic up-chirps from 2 kHz to 16 kHz, with 5 ms duration at 80 s −1 ). This was achieved using optimised electrode type and placement, improved bone conductor and bio-amplifier design, and a streamlined placement and retention of the electrodes and bone conductor with an over-the-head elastic strap. We masked the contralateral ear’s response with wideband noise to ensure responses were from the operated ear only. Using custom-written software, we automatically adjusted chirp intensity to maintain the brainstem’s auditory steady state response (ASSR) near a fixed amplitude (‘the ASSR target’), set to an amplitude just above our system’s measurement noise floor. The chirp intensity required to maintain this target amplitude was defined as the patient’s ‘ASSR threshold’. Main results Our improvements allowed us to rapidly track hearing threshold continuously for the entire duration of middle ear surgery in fully anaesthetised patients, with the ASSR threshold initially within 10 dB of psychoacoustic threshold just before surgery. The system can track threshold changes rapidly, but can be limited by background acoustic masking noise in the operating room. Significance Our system could provide surgeons with a rapid and sensitive display of cochlear sensitivity during middle ear procedures, and help identify and possibly avoid traumatic manipulations that cause iatrogenic hearing loss.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Arthur Emmett Research Institute, Perth, Australia.
- University of Otago, Christchurch, New Zealand.
ORCID-Profile: Robert B Patuzzi, Alison M Cook, Michael J Bergin
Zitieren
APA
Patuzzi, R. B., Cook, A. M., Bergin, M. J., & Bird, P. A. (2026). Continuous fast tracking of auditory threshold during middle ear surgery using the auditory steady state response (ASSR). Physiological Measurement, 47(8), 085005. https://doi.org/10.1088/1361-6579/ae9032
Vancouver
Patuzzi RB, Cook AM, Bergin MJ, Bird PA. Continuous fast tracking of auditory threshold during middle ear surgery using the auditory steady state response (ASSR). Physiological Measurement. 2026;47(8):085005. doi:10.1088/1361-6579/ae9032
BibTeX
@article{Patuzzi2026,
author = {Patuzzi, Robert B and Cook, Alison M and Bergin, Michael J and Bird, Philip A},
title = {Continuous fast tracking of auditory threshold during middle ear surgery using the auditory steady state response (ASSR)},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {8},
pages = {085005},
doi = {10.1088/1361-6579/ae9032}
}