EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of activPAL and ActiGraph measured moderate to vigorous physical activity in people with COPD

Jung Yoen Son iD, Katelyn Webster-Dekker iD, Deanna J Marriot, She'Lon Tucker iD, Janet L Larson iD

Physiological Measurement · 31.08.2026 · 47 (8) · 085017

DOI: 10.1088/1361-6579/ae87f1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Physiological Measurement, online erschienen am 13.08.2026. Verfasst von Jung Yoen Son und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Yale School of Medicine, 333 Cedar St, New Haven, CT 06510, United States of America. Hauptthemen laut MEDLINE: Actigraphy, Pulmonary Disease, Chronic Obstructive, Exercise, Accelerometry. Die Arbeit nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIA NIH HHS, NINR NIH HHS, National Clinician Scholars Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. ActiGraph accelerometers are commonly used to assess moderate-to-vigorous physical activity (MVPA), but there are concerns about missing data due to compliance issues with hip-worn devices. ActivPAL devices are worn 24 h d −1 on the anterior thigh, minimizing missing data, but activPAL software does not directly estimate MVPA. This study aimed to evaluate the agreement between MVPA derived from activPAL (using five methods) and ActiGraph data (using two methods) among individuals with chronic obstructive pulmonary disease (COPD). Approach . In this secondary analysis, 148 inactive adults aged ≥ 50 years with COPD wore an activPAL3 on the thigh and an ActiGraph GT9X on the hip concurrently for 7 days. MVPA was estimated from activPAL using five methods: 1) metabolic equivalents, 2) ≥ 75 steps/min, 3) ≥ 100 steps/min, 4) vector magnitude (VM) counts, and 5) vertical-axis counts, and from ActiGraph using Freedson VM3 (2011) and Evenson VM (2023) cut-points, 60-s epochs, and normal filters. We assessed agreement between activPAL and ActiGraph MVPA using concordance correlation coefficients (CCCs), two one-sided t-tests (TOST), and Bland–Altman plots. Main Results . Compared with ActiGraph MVPA using Freedson VM3, CCCs ranged from 0.51 to 0.53 across activPAL methods, except for ≥ 100 steps/min (CCC = 0.42); four of five activPAL methods were equivalent at a ±8 min d −1 equivalence margin. Compared with ActiGraph MVPA using Evenson, CCCs ranged from 0.20 to 0.25 across activPAL methods, and no activPAL method was equivalent. Significance . ActivPAL MVPA showed moderate group-level agreement and equivalence when compared to ActiGraph MVPA using Freedson VM3. Findings suggest activPAL may estimate group-level MVPA in this population, though further research is needed to validate this approach for individual-level MVPA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ActigraphyPulmonary Disease, Chronic ObstructiveExerciseAccelerometryHumansMiddle AgedMaleFemale

Stichwörter der Autor:innen

ActiGraphyaccelerometryactivPALmoderate to vigorous physical activityphysical activity

Autor:innen und Institutionen

  • Department of Internal Medicine, Yale School of Medicine, 333 Cedar St, New Haven, CT 06510, United States of America.
  • University of Michigan, School of Nursing, 400 North Ingalls St, Ann Arbor, MI 48109, United States of America.

ORCID-Profile: Jung Yoen Son, Katelyn Webster-Dekker, She'Lon Tucker, Janet L Larson

Förderung

  • NIA NIH HHS
  • NINR NIH HHS
  • National Clinician Scholars Program
  • National Institute on Aging
  • National Institute of Nursing Research

Zitieren

APA

Son, J. Y., Webster-Dekker, K., Marriot, D. J., Tucker, S., & Larson, J. L. (2026). Comparison of activPAL and ActiGraph measured moderate to vigorous physical activity in people with COPD. Physiological Measurement, 47(8), 085017. https://doi.org/10.1088/1361-6579/ae87f1

Vancouver

Son JY, Webster-Dekker K, Marriot DJ, Tucker S, Larson JL. Comparison of activPAL and ActiGraph measured moderate to vigorous physical activity in people with COPD. Physiological Measurement. 2026;47(8):085017. doi:10.1088/1361-6579/ae87f1

BibTeX
@article{Son2026,
  author = {Son, Jung Yoen and Webster-Dekker, Katelyn and Marriot, Deanna J and Tucker, She'Lon and Larson, Janet L},
  title = {Comparison of activPAL and ActiGraph measured moderate to vigorous physical activity in people with COPD},
  journal = {Physiological Measurement},
  year = {2026},
  volume = {47},
  number = {8},
  pages = {085017},
  doi = {10.1088/1361-6579/ae87f1}
}
Kostenlos starten →