EdgeECG: a lightweight edge-oriented network with dual criterion pruning for real-time ECG arrhythmia classification
Physiological Measurement · 29.05.2026 · 47 (5) · 055014
DOI: 10.1088/1361-6579/ae696a ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 18.05.2026. Verfasst von Jiayan Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Systems Engineering, Automation and Industrial Informatics, Polytechnic University of Catalonia, Barcelona, Spain. Hauptthemen laut MEDLINE: Electrocardiography, Arrhythmias, Cardiac, Convolutional Neural Networks. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Joint Funds for the Innovation of Science and Technology in Fujian Province, National Natural Science Foundation of China, Natural Science Foundation of Fujian Province.
Abstract (Originalsprache)
Objective. Miniature electrocardiogram (ECG) devices can rapidly and accurately acquire real-time cardiac signals, enabling timely warnings for patients with heart disease. To achieve accurate arrhythmia classification on resource-constrained ECG edge devices, we propose EdgeECG, an ultra-lightweight neural network designed for deployment on low-power microcontrollers. Approach. EdgeECG is first designed with a compact convolutional architecture to ensure compatibility with resource-limited embedded platforms. A dual criterion pruning (DCP) strategy is then introduced to evaluate weight importance using both magnitude and median deviation for more precise model compression. In addition, quantization is applied to reduce storage cost and improve deployment efficiency on an STM32F103 microcontroller. Main results. Experimental results on the benchmark MIT-BIH arrhythmia dataset show that EdgeECG achieves an overall classification accuracy of 98.07%, outperforming several representative methods. In patient-independent record-level evaluation, the accuracy reaches 80.73%. The model contains only 2680 parameters and is successfully deployed on an STM32F103 microcontroller with 64 KB SRAM, achieving an inference latency of 0.025 s and an energy consumption of 0.156 mJ per inference. In addition, DCP reduces the number of non-zero parameters by nearly 50% while maintaining promising classification performance. Significance. EdgeECG provides an effective solution for five-class ECG arrhythmia classification on severely resource-constrained edge devices. Its compact architecture, effective pruning strategy, and successful deployment on an STM32F103 demonstrate its potential for low-power edge-based ECG analysis and wearable cardiac monitoring applications. The source code of EdgeECG is publicly available at: https://github.com/jyanhuang/EdgeECG-code .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Systems Engineering, Automation and Industrial Informatics, Polytechnic University of Catalonia, Barcelona, Spain.
- College of Computer and Data Science, Putian University, Putian, People's Republic of China.
- College of Artificial Inteligence, Putian University, Putian, People's Republic of China.
- Faculty of Data Science, City University of Macau, Macau, People's Republic of China.
- Engineering Research Center of Big Data Application in Private Health Medicine, Fujian Province University, Putian, People's Republic of China.
- Fujian Provincial Key Laboratory of Information Processing and Intelligent Control, School of Computer and Big Data, Minjiang University, Fuzhou, People's Republic of China.
ORCID-Profile: Jiayan Huang, Antoni Grau, Zuoyong Li
Förderung
- Joint Funds for the Innovation of Science and Technology in Fujian Province
- National Natural Science Foundation of China
- Natural Science Foundation of Fujian Province
- China Scholarship Council
- Open Project of Fujian Key Laboratory of Medical Big Data Engineering
- Open Foundation of the Engineering Research Center of Big Data Application in Private Health Medicine of Fujian Province University
- Talent Introduction Projects (Seedling Fund) of Putian University
- Putian Science and Technology Plan Project
Zitieren
APA
Huang, J., Wang, C., Grau, A., Xiao, Y., Luo, S., Che, Y., & Li, Z. (2026). EdgeECG: a lightweight edge-oriented network with dual criterion pruning for real-time ECG arrhythmia classification. Physiological Measurement, 47(5), 055014. https://doi.org/10.1088/1361-6579/ae696a
Vancouver
Huang J, Wang C, Grau A, Xiao Y, Luo S, Che Y, et al. EdgeECG: a lightweight edge-oriented network with dual criterion pruning for real-time ECG arrhythmia classification. Physiological Measurement. 2026;47(5):055014. doi:10.1088/1361-6579/ae696a
BibTeX
@article{Huang2026,
author = {Huang, Jiayan and Wang, Chuansheng and Grau, Antoni and Xiao, Yongyi and Luo, Shaoye and Che, Yan and Li, Zuoyong},
title = {EdgeECG: a lightweight edge-oriented network with dual criterion pruning for real-time ECG arrhythmia classification},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {5},
pages = {055014},
doi = {10.1088/1361-6579/ae696a}
}
EUVIMED