Automatic sleep staging from CPAP airflow using a dual fusion multi-period convolutional neural network
Physiological Measurement · 30.04.2026 · 47 (4) · 045011
DOI: 10.1088/1361-6579/ae60df ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, online erschienen am 29.04.2026. Verfasst von Hsin-Yu Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: PranaQ Pte. Ltd., Singapore, Singapore. Hauptthemen laut MEDLINE: Convolutional Neural Networks, Continuous Positive Airway Pressure, Sleep Stages, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben.
Abstract (Originalsprache)
Background
Continuous positive airway pressure (CPAP) therapy is the standard treatment for obstructive sleep apnea-hypopnea syndrome, yet its use as a passive sleep dynamics monitoring remains limited. CPAP devices record only airflow signals, called CPAP-flow, which constantly interact with the pressure delivered by the device. This interaction renders the signal vulnerable to device-related artifacts and inter-/intra-patient variability, posing significant challenges to its repurposing for monitoring sleep dynamics.
Methods
Motivated by neural network-based studies of sleep-wake transition from CPAP-flow, we leverage existing physiological knowledge and introduce a dual fusion multi-period convolutional neural network (DFMP-CNN) model. This deep learning architecture leverages multiple period-specific convolutional kernels and a dual-fusion mechanism to jointly encode known short- and long-range temporal dependencies in CPAP-flow, overcoming limitations of traditional fixed-scale models.
Results
Extensive experiments demonstrate that DFMP-CNN achieves state-of-the-art performance in CPAP-based sleep staging. On the Yale dataset, it achieves 78.5% accuracy (Cohen’s κ = 0.605), with a best case of κ = 0.886; on the Duke dataset, it reaches 73.6% accuracy ( κ = 0.524), with a best case of κ = 0.805. Cross-dataset evaluations confirm the model’s transferability across clinical centers and device types, while feature and fusion ablation studies highlight its robustness.
Conclusions
DFMP-CNN provides an unobtrusive approach for sleep monitoring using CPAP devices, providing a dual-purpose platform for therapy and longitudinal assessment. Significance: the robust performance of DFMP-CNN across datasets and device types underscores its potential to improve clinical assessment and optimize therapy management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- PranaQ Pte. Ltd., Singapore, Singapore.
- Department of Medicine, Yale University School of Medicine, New Haven, CT, United States of America.
- Duke Department of Neurology,Durham, NC, United States of America.
- Courant Institute of Mathematical Sciences, New York University, New York, NY, United States of America.
- PranaQ, Co., New York, NY, United States of America.
ORCID-Profile: Hsin-Yu Chen
Zitieren
APA
Chen, H. Y., Ahsan, M., Zinchuk, A. V., Husain, A., Yaggi, H. K., Wu, H. T., & Chen, C. Y. (2026). Automatic sleep staging from CPAP airflow using a dual fusion multi-period convolutional neural network. Physiological Measurement, 47(4), 045011. https://doi.org/10.1088/1361-6579/ae60df
Vancouver
Chen HY, Ahsan M, Zinchuk AV, Husain A, Yaggi HK, Wu HT, et al. Automatic sleep staging from CPAP airflow using a dual fusion multi-period convolutional neural network. Physiological Measurement. 2026;47(4):045011. doi:10.1088/1361-6579/ae60df
BibTeX
@article{Chen2026,
author = {Chen, Hsin-Yu and Ahsan, Muneeb and Zinchuk, Andrey V and Husain, Aatif and Yaggi, Henry K and Wu, Hau-Tieng and Chen, Cheng-Yao},
title = {Automatic sleep staging from CPAP airflow using a dual fusion multi-period convolutional neural network},
journal = {Physiological Measurement},
year = {2026},
volume = {47},
number = {4},
pages = {045011},
doi = {10.1088/1361-6579/ae60df}
}
EUVIMED