An electrical pulse artifact signal for estimating arterial blood pressure: a proof-of-concept study
Physiological Measurement · 2025
DOI: 10.1088/1361-6579/ae2aa7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiological Measurement, 2025. Verfasst von Ali Howidi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, University of Toronto, Toronto, Canada. Hauptthemen laut MEDLINE: Blood Pressure Determination, Artifacts, Signal Processing, Computer-Assisted, Arterial Pressure. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.
Abstract (Originalsprache)
Objective. Hypertension is a leading cause of mortality worldwide, for which myriad treatment options are available. It is widely considered that continuous measurement of arterial blood pressure (BP) could improve the treatment of hypertension; however, chronically monitoring patient BP remains a significant challenge. In this study, we investigated a novel approach that uses an implantable electrode to generate an artifact signal for predicting arterial BP. Approach. In isoflurane anesthetized rats ( n = 10, male), the right common carotid artery was instrumented with a multi-contact cuff electrode to acquire the artifact signal—termed the electro-vascular-gram (EVG) and the contralateral common carotid artery was catheterized to measure intra-arterial BP. The EVG signals were processed (e.g. extract Catch22 features) and applied to linear regression, random forest (RF) regressor, and convolutional neural network models to predict systolic and diastolic BP. Main results. Among the various models tested with the EVG data, the RF model + Catch22 features method achieved the highest performance, yielding predicted BP values (error < 5 mmHg) in 82.6%–100% and 84.1%–99.9% of the testing set for systolic and diastolic, respectively. A 5-fold cross-validation demonstrated similar performance by predicting BP values (error < 5 mmHg) in 91.5 ± 0.1% and 92.4 ± 0.1% of testing data for systolic and diastolic, respectively. Significance. This proof-of-concept study supports the feasibility of using an implantable electrode and machine learning models for potentially measuring arterial BP in continuous fashion. Further system development is warranted prior to clinical translation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada.
- KITE Research Institute, Toronto Rehabilitation Institute, University Health Network, Toronto, Canada.
- Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada.
ORCID-Profile: Ryan G L Koh, Niveetha Wijendran, Paul B Yoo
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation
Zitieren
APA
Howidi, A., Koh, R. G. L., Wijendran, N., Omidian, K., Chhajer, K., & Yoo, P. B. (2025). An electrical pulse artifact signal for estimating arterial blood pressure: a proof-of-concept study. Physiological Measurement. https://doi.org/10.1088/1361-6579/ae2aa7
Vancouver
Howidi A, Koh RGL, Wijendran N, Omidian K, Chhajer K, Yoo PB. An electrical pulse artifact signal for estimating arterial blood pressure: a proof-of-concept study. Physiological Measurement. 2025. doi:10.1088/1361-6579/ae2aa7