EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhancements and reference internal dosimetry data for the MOBY whole-body computational phantom of the laboratory mouse

Natalia Carrasco-Rojas, Robert J Dawson iD, Chansoo Choi iD, Andrew Sforza, Bangho Shin iD, Nicole Strecker iD, Lukas Carter iD, Chris Beekman iD, Paul W Segars, Adam Kesner iD, Harald Paganetti iD, Wesley E Bolch iD

Physics in Medicine & Biology · 28.11.2026 · 71 (22) · 225001

DOI: 10.1088/1361-6560/aeb792 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 05.11.2026. Verfasst von Natalia Carrasco-Rojas und 11 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Program, College of Medicine , University of Florida, 1275 Center Drive, Gainesville, Florida, 32611, United States. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: US Department of Energy, National Research Foundation of Korea, US National Institute of Allergy and Infectious Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Computational phantoms play a crucial role in preclinical studies, particularly for internal dosimetry applications. While the mouse whole-body (MOBY) phantom has been widely used in Monte Carlo radiation transport simulations, several anatomical limitations restrict its dosimetric accuracy. This study introduces enhanced tetrahedral mesh-based MOBY phantoms, in male and female versions, featuring refined skeletal structures, improved anatomical representation, and an extended and standardized blood distribution model to support small animal dosimetry. Approach . The MOBY polygon mesh representation served as the foundation for phantom development. Using the 3D modeling software, Blender, organ and skeletal structures were refined to eliminate mesh intersections while preserving anatomical integrity. The skeleton was segmented into cortical, spongiosa and medullary cavity regions, and a spinal cord was incorporated into the vertebral foramina. The male model was finalized by adding a prostate and subsequently modified to create the female counterpart by replacing male-specific structures with the uterus and ovaries. Additional anatomical refinements included lymph nodes, Peyer’s patches, bronchial wall and primary blood vessels, with organ-specific blood volumes calculated for estimating bulk tissue densities. Each phantom was rigidly scaled to yield six phantoms of different total body mass for each sex. Main Results . A total of twelve anatomically enhanced MOBY phantoms were developed in tetrahedral format. Monte Carlo radiation transport simulations were performed and SAFs and S -values for different radionuclides were computed, establishing a robust dataset for preclinical radiation dosimetry for inclusion in the MIRDcalc software code. Significance . The refined MOBY phantoms provide a critical advancement in preclinical dosimetry by incorporating sex-specific anatomical details, an improved skeletal model, and enhanced organ-level dose assessments. These phantoms will facilitate dose-response radiopharmaceutical research and support the integration of murine dosimetry models into human dose estimation frameworks.

Schlagwörter

Stichwörter der Autor:innen

computational phantomsmurine modelpreclinical studiesradiopharmaceutical dosimetry

Autor:innen und Institutionen

  • Medical Physics Program, College of Medicine , University of Florida, 1275 Center Drive, Gainesville, Florida, 32611, United States.
  • Medical Physics Program, College of Medicine , University of Florida, 1275 Center Drive, BMES JG-56, Gainesville, Florida, 32611, United States.
  • Biomedical Engineering, University of Florida, 1275 Center Drive, Gainesville, 32611-7011, United States.
  • J Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, 1275 Center Drive, Gainesville, Florida, 32611-7011, United States.
  • University of Wisconsin-Madison, Department of Radiology, Madison, Wisconsin, 53706-1314, United States.
  • Medical Physics, Memorial Sloan Kettering Cancer Center, 1250 1st Avenue, 10065, New York, NY, United States.

ORCID-Profile: Robert J Dawson, Chansoo Choi, Bangho Shin, Nicole Strecker, Lukas Carter, Chris Beekman, Adam Kesner, Harald Paganetti, Wesley E Bolch

Förderung

  • US Department of Energy
  • National Research Foundation of Korea
  • US National Institute of Allergy and Infectious Diseases
  • US National Institute for Biomedical Imaging and Bioengineering
  • US National Cancer Institute

Zitieren

APA

Carrasco-Rojas, N., Dawson, R. J., Choi, C., Sforza, A., Shin, B., Strecker, N., Carter, L., Beekman, C., Segars, P. W., Kesner, A., Paganetti, H., & Bolch, W. E. (2026). Enhancements and reference internal dosimetry data for the MOBY whole-body computational phantom of the laboratory mouse. Physics in Medicine & Biology, 71(22), 225001. https://doi.org/10.1088/1361-6560/aeb792

Vancouver

Carrasco-Rojas N, Dawson RJ, Choi C, Sforza A, Shin B, Strecker N, et al. Enhancements and reference internal dosimetry data for the MOBY whole-body computational phantom of the laboratory mouse. Physics in Medicine & Biology. 2026;71(22):225001. doi:10.1088/1361-6560/aeb792

BibTeX
@article{CarrascoRojas2026,
  author = {Carrasco-Rojas, Natalia and Dawson, Robert J and Choi, Chansoo and Sforza, Andrew and Shin, Bangho and Strecker, Nicole and Carter, Lukas and Beekman, Chris and Segars, Paul W and Kesner, Adam and Paganetti, Harald and Bolch, Wesley E},
  title = {Enhancements and reference internal dosimetry data for the MOBY whole-body computational phantom of the laboratory mouse},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {22},
  pages = {225001},
  doi = {10.1088/1361-6560/aeb792}
}
Kostenlos starten →