EUVIMEDEUVIMED entdecken
Crossref

Study on the capture and thrombolytic efficacy of magnetic particle clusters under a deeply focused rotating magnetic field

Shoulong Dong iD, Zongnan Liu, Yuan Lei iD, Sizhe Xiang, Lisheng Zhao, Dengfeng He iD, Chenguo Yao

Physics in Medicine & Biology · 14.11.2026 · 71 (21) · 215030

DOI: 10.1088/1361-6560/aeb643 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 12.11.2026. Verfasst von Shoulong Dong und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Chongqing University, Chongqing 400044, People's Republic of China. Hauptthemen laut MEDLINE: Magnetic Fields, Thrombolytic Therapy. Die Arbeit nennt 46 Literaturangaben. Gefördert von: Research and Innovation Foundation of Chongqing, Chongqing Health Commission Young Top Talents, Chongqing Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Magnetic particles can serve as carriers for tissue plasminogen activator (tPA) and can be targeted and controllably manipulated under a rotating magnetic field (RMF), providing a potential approach for localized thrombolysis in venous thrombosis. However, current magnetic-control strategies remain limited at larger working distances and under flow conditions because of magnetic-field attenuation, insufficient focusing capability, and blood-flow-induced washout. Therefore, maintaining effective capture and stable motion of magnetic particle clusters (MPCs) remains an important challenge. Approach. To address this issue, we developed a deeply focused rotating magnetic field (DF-RMF) system driven by two synchronously rotating permanent magnets. The system generates a magnetic-field region with an axial dual-peak distribution and centripetal action, thereby promoting MPC accumulation within the target region while maintaining rotational motion. Numerical simulations and in vitro experiments were conducted to evaluate the magnetic-field characteristics, MPC rotational behavior, capture performance under flow conditions, and thrombolytic efficacy. Experiments were performed in phosphate-buffered saline (PBS) and a glycerol–water solution (GWS) with higher blood-relevant viscosity. Main results. Compared with a single-permanent-magnet rotating magnetic field, the DF-RMF provided better particle capture performance at larger working distances. In PBS, particle capture could still be maintained to some extent at a working distance of 5 cm, while particle retention was still observed at a flow velocity of 14 cm s −1 and a working distance of 2 cm. Experiments in GWS showed that higher blood-relevant viscosity reduced the long-distance capture capability of the DF-RMF. Finite-element simulations showed that MPC rotation generated localized recirculating flow, velocity gradients, and periodic pressure variations in the surrounding fluid, potentially facilitating tPA transport near the thrombus interface. In the fully occluded thrombus model, the DF-RMF-assisted group achieved complete recanalization, with a thrombus clearance rate approximately five times that of the tPA-only group. Significance. The DF-RMF improved the long-distance capture and anti-washout retention of magnetic particles under flow conditions and enhanced the in vitro thrombolytic effect of tPA, providing a new approach for magnetically assisted thrombolysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic FieldsThrombolytic TherapyRotation

Stichwörter der Autor:innen

deep focusingmagnetic particle clustersrotating magnetic fieldsynergistic thrombolysistargeted thrombolysis

Autor:innen und Institutionen

  • School of Electrical Engineering, Chongqing University, Chongqing 400044, People's Republic of China.
  • Institute of Burn Research Southwest Hospital, Third Military Medical University (Army Medical Univer-sity), Chongqing 400038, People's Republic of China.

ORCID-Profile: Shoulong Dong, Yuan Lei, Dengfeng He

Förderung

  • Research and Innovation Foundation of Chongqing
  • Chongqing Health Commission Young Top Talents
  • Chongqing Natural Science Foundation
  • Natural Science Foundation of China
  • Chongqing Science-Health Joint Medical Research Foundation

Zitieren

APA

Dong, S., Liu, Z., Lei, Y., Xiang, S., Zhao, L., He, D., & Yao, C. (2026). Study on the capture and thrombolytic efficacy of magnetic particle clusters under a deeply focused rotating magnetic field. Physics in Medicine & Biology, 71(21), 215030. https://doi.org/10.1088/1361-6560/aeb643

Vancouver

Dong S, Liu Z, Lei Y, Xiang S, Zhao L, He D, et al. Study on the capture and thrombolytic efficacy of magnetic particle clusters under a deeply focused rotating magnetic field. Physics in Medicine & Biology. 2026;71(21):215030. doi:10.1088/1361-6560/aeb643

BibTeX
@article{Dong2026,
  author = {Dong, Shoulong and Liu, Zongnan and Lei, Yuan and Xiang, Sizhe and Zhao, Lisheng and He, Dengfeng and Yao, Chenguo},
  title = {Study on the capture and thrombolytic efficacy of magnetic particle clusters under a deeply focused rotating magnetic field},
  journal = {Physics in Medicine & Biology},
  year = {2026},
  volume = {71},
  number = {21},
  pages = {215030},
  doi = {10.1088/1361-6560/aeb643}
}