Microdosimetric kinetic model for enhanced estimation of cell survival in aerobic human salivary gland cells under heavy ion irradiation
Physics in Medicine & Biology · 14.05.2026 · 71 (9) · 095006
DOI: 10.1088/1361-6560/ae5d82 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 29.04.2026. Verfasst von Tae Ho Jang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Program in Bioengineering, Graduate School, Seoul National University, Seoul, 151-742, Republic of Korea. Hauptthemen laut MEDLINE: Models, Biological, Salivary Glands, Heavy Ion Radiotherapy. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korean governmen.
Abstract (Originalsprache)
Objective. Accurate estimation of cell survival fractions across a broad range of linear energy transfer (LET) is essential for precise heavy ion therapy planning. The microdosimetric kinetic (MK) model predicts cell survival from microdosimetric quantities; however, most closed-form MK formulations treat the quadratic coefficient β as a constant, which limits predictive accuracy under high-LET irradiation. This study aimed to develop a revised MK model that overcomes this limitation by redefining β as an LET-dependent function. Approach. The revised MK model incorporates the saturation-corrected dose-mean specific energy into the formulation of β . Model performance was evaluated against the reference MK model using 324 reconstructed survival fraction data points from 54 irradiation conditions of aerobic human salivary gland tumor cells exposed to helium, carbon, and neon ions. Parameter estimation was performed using a log-scaled mean squared error loss optimized through a hybrid global–local scheme. Main results. At low LET, both the revised and reference models reproduced experimental survival with comparable accuracy. However, at higher LET, the revised model maintained stable agreement with experimental data, whereas the reference model diverged markedly due to excessive curvature in its predictions. Across the entire experimental LET range, the revised model consistently reproduced cell survival data more accurately than the reference model. Significance. These findings demonstrate that redefining the quadratic coefficient as an LET-dependent term substantially improves the predictive accuracy of the MK model under high-LET and wide-dose conditions. The proposed model enhances radiobiological modeling performance while preserving the structural simplicity and compatibility of the existing MK framework.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interdisciplinary Program in Bioengineering, Graduate School, Seoul National University, Seoul, 151-742, Republic of Korea.
- Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea.
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea.
- Project Group of the Gijang Heavy Ion Medical Accelerator, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea.
ORCID-Profile: Tae Ho Jang, Hyung Jin Choun, Eun Taek Yoon, Sung Hyun Lee, Jong Min Park
Förderung
- Korean governmen
Zitieren
APA
Jang, T. H., Choun, H. J., Yoon, E. T., Lee, S. H., & Park, J. M. (2026). Microdosimetric kinetic model for enhanced estimation of cell survival in aerobic human salivary gland cells under heavy ion irradiation. Physics in Medicine & Biology, 71(9), 095006. https://doi.org/10.1088/1361-6560/ae5d82
Vancouver
Jang TH, Choun HJ, Yoon ET, Lee SH, Park JM. Microdosimetric kinetic model for enhanced estimation of cell survival in aerobic human salivary gland cells under heavy ion irradiation. Physics in Medicine & Biology. 2026;71(9):095006. doi:10.1088/1361-6560/ae5d82
BibTeX
@article{Jang2026,
author = {Jang, Tae Ho and Choun, Hyung Jin and Yoon, Eun Taek and Lee, Sung Hyun and Park, Jong Min},
title = {Microdosimetric kinetic model for enhanced estimation of cell survival in aerobic human salivary gland cells under heavy ion irradiation},
journal = {Physics in Medicine & Biology},
year = {2026},
volume = {71},
number = {9},
pages = {095006},
doi = {10.1088/1361-6560/ae5d82}
}
EUVIMED