Microdosimetric evaluation of a clinical carbon ion beam using a tissue-equivalent proportional counter
Physics in Medicine & Biology · 2025
DOI: 10.1088/1361-6560/adeb3e ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2025. Verfasst von Shannon Hartzell und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America. Hauptthemen laut MEDLINE: Heavy Ion Radiotherapy, Radiometry, Carbon. Die Arbeit nennt 42 Literaturangaben. Gefördert von: NIH HHS, University of Texas MD Anderson Cancer Center, National Institutes of Health.
Abstract (Originalsprache)
Objective . Microdosimetry provides critical insights into radiation quality and relative biological effectiveness (RBE) in carbon ion therapy. However, its application in modern pulsed scanning beams is limited due to detector response challenges at high dose rates. This study evaluates the feasibility of using a commercially available spherical tissue-equivalent proportional counter (TEPC) (linear energy transfer (LET)-1/2, Far West Technologies) to measure microdosimetric spectra in a clinical carbon ion beam, comparing results with Monte Carlo simulations. Approach. Microdosimetric measurements were performed at the National Center for Oncological Hadrontherapy using the LET-1/2 filled with 33.1 mmHg tissue-equivalent gas to simulate a 1 μ m diameter tissue volume. Measurements were conducted at various depths and beam energies, covering a range of LETs. Data were processed to obtain frequency- and dose-weighted lineal energy distributions, from which saturation-corrected dose-mean lineal energy values and RBE calculated with the modified microdosimetric kinetic model were derived. Monte Carlo simulations using TOPAS replicated the experimental setup for comparison. Main Results. TEPC measurements demonstrated reasonable agreement with Monte Carlo simulations when the beam intensity was sufficiently reduced to mitigate pulse pileup. At the standard clinical beam intensity, microdosimetric spectra exhibited distortions due to pulse pileup effects, leading to overestimation of high lineal energy events. However, when the lowest-intensity synchrotron mode was used to achieve reduced beam intensities (∼1.5 × 10 5 particles s −1 ), agreement between measured and simulated spectra improved significantly, with RBE values derived from the measured spectra agreeing with Monte Carlo predictions to
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL, United States of America.
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.
- Independent Researcher.
- Medical Physics, Clinical Department, CNAO National Center for Oncological Hadrontherapy, Pavia, Italy.
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.
ORCID-Profile: Shannon Hartzell, Phillip J Taddei, Fada Guan
Förderung
- NIH HHS
- University of Texas MD Anderson Cancer Center
- National Institutes of Health
Zitieren
APA
Hartzell, S., Taddei, P. J., Guan, F., Mirandola, A., Taylor, P., Ciocca, M., Magro, G., Peterson, C. B., & Kry, S. (2025). Microdosimetric evaluation of a clinical carbon ion beam using a tissue-equivalent proportional counter. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/adeb3e
Vancouver
Hartzell S, Taddei PJ, Guan F, Mirandola A, Taylor P, Ciocca M, et al. Microdosimetric evaluation of a clinical carbon ion beam using a tissue-equivalent proportional counter. Physics in Medicine & Biology. 2025. doi:10.1088/1361-6560/adeb3e
BibTeX
@article{Hartzell2025,
author = {Hartzell, Shannon and Taddei, Phillip J and Guan, Fada and Mirandola, Alfredo and Taylor, Paige and Ciocca, Mario and Magro, Giuseppe and Peterson, Christine B and Kry, Stephen},
title = {Microdosimetric evaluation of a clinical carbon ion beam using a tissue-equivalent proportional counter},
journal = {Physics in Medicine & Biology},
year = {2025},
doi = {10.1088/1361-6560/adeb3e}
}
EUVIMED