EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of pectoral muscle removal on deep-learning-based breast cancer risk prediction

Zan Klanecek iD, Yao-Kuan Wang iD, Tobias Wagner, Lesley Cockmartin, Nicholas Marshall iD, Brayden Schott iD, Ali Deatsch iD, Andrej Studen, Katja Jarm, Mateja Krajc, Miloš Vrhovec iD, Hilde Bosmans und 1 weitere

Physics in Medicine & Biology · 2025

DOI: 10.1088/1361-6560/adb367 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2025. Verfasst von Zan Klanecek und 12 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mathematics and Physics, Medical Physics, University of Ljubljana, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Deep Learning, Pectoralis Muscles, Breast Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Foundation - Flanders, Javna Agencija za Raziskovalno Dejavnost RS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

State-of-the-art breast cancer risk (BCR) prediction models have been originally trained on mammograms with pectoral muscle (PM) included. This study investigated whether excluding PM during training/fine-tuning improves the model’s BCR discrimination performance, calibration, and robustness. Approach. First, the Original deep learning model (MIRAI), trained on the US (Massachusetts General Hospital) data, was validated, and the relative contribution of PM to BCR predictions was evaluated using saliency maps. Additionally, 23 792 mammograms from the Slovenian screening program were collected and two datasets were created, with and without screening positive exams. The original MIRAI was then fine-tuned on the training/fine-tuning set of Slovenian mammograms with and without PM, creating Fine-tuned MIRAI models. In total, four models (Original MIRAI with PM, Original MIRAI without PM, Fine-tuned MIRAI with PM, Fine-tuned MIRAI without PM) were compared on a test set in terms of discrimination performance for 1–5 Year BCR (evaluating area under the curve), calibration performance (measured with expected calibration error—ECE) and robustness to incremental PM removals/additions, and to incremental breast tissue removals.

Results

The relative contribution of PM to the BCR prediction on the Original MIRAI model was low (∼5%); however, there were significant outliers where the relative contribution was more than 50%. The removal of PM did not impact the 1–5 Year BCR discrimination performance of the Original MIRAI (with screening positive exams: 0.77–0.91, without screening positive exams: 0.64–0.67). Fine-tuned MIRAI on mammograms with PM removed achieved significantly higher 1-5 Year BCR discrimination performance (with screening positive exams: 0.82–0.93, without screening positive exams: 0.71–0.79). After recalibration, all models had similar ECE (with screening positive exams: 0.04–0.05, without screening positive exams: 0.02–0.03). Significance. Improved BCR discrimination performance can be achieved when the model is trained/fine-tuned on mammograms with PM removed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningPectoralis MusclesBreast NeoplasmsHumansMammographyFemaleRisk AssessmentRiskMiddle AgedCalibration

Stichwörter der Autor:innen

breast cancer riskcalibrationconvolutional neural networksdeep learningmammographypectoral musclerobustness

Autor:innen und Institutionen

  • Faculty of Mathematics and Physics, Medical Physics, University of Ljubljana, Ljubljana, Slovenia.
  • Department of Imaging and Pathology, Division of Medical Physics & Quality Assessment, KU Leuven, Leuven, Belgium.
  • Department of Radiology, UZ Leuven, Leuven, Belgium.
  • Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, United States of America.
  • Jožef Stefan Institute, Ljubljana, Slovenia.
  • Institute of Oncology Ljubljana, Ljubljana, Slovenia.

ORCID-Profile: Zan Klanecek, Yao-Kuan Wang, Nicholas Marshall, Brayden Schott, Ali Deatsch, Miloš Vrhovec, Robert Jeraj

Förderung

  • Research Foundation - Flanders
  • Javna Agencija za Raziskovalno Dejavnost RS

Zitieren

APA

Klanecek, Z., Wang, Y. K., Wagner, T., Cockmartin, L., Marshall, N., Schott, B., Deatsch, A., Studen, A., Jarm, K., Krajc, M., Vrhovec, M., Bosmans, H., & Jeraj, R. (2025). Impact of pectoral muscle removal on deep-learning-based breast cancer risk prediction. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/adb367

Vancouver

Klanecek Z, Wang YK, Wagner T, Cockmartin L, Marshall N, Schott B, et al. Impact of pectoral muscle removal on deep-learning-based breast cancer risk prediction. Physics in Medicine & Biology. 2025. doi:10.1088/1361-6560/adb367

BibTeX
@article{Klanecek2025,
  author = {Klanecek, Zan and Wang, Yao-Kuan and Wagner, Tobias and Cockmartin, Lesley and Marshall, Nicholas and Schott, Brayden and Deatsch, Ali and Studen, Andrej and Jarm, Katja and Krajc, Mateja and Vrhovec, Miloš and Bosmans, Hilde and Jeraj, Robert},
  title = {Impact of pectoral muscle removal on deep-learning-based breast cancer risk prediction},
  journal = {Physics in Medicine & Biology},
  year = {2025},
  doi = {10.1088/1361-6560/adb367}
}
Kostenlos starten →