Self-normalization for a 1 mm 3 resolution clinical PET system using deep learning
Physics in Medicine & Biology · 2024
DOI: 10.1088/1361-6560/ad69fb ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2024. Verfasst von Myungheon Chin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America. Hauptthemen laut MEDLINE: Deep Learning, Positron-Emission Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Emerson Collective Cancer Research Fund, Wallace H Coulter Foundation, Finnish Cultural Foundation.
Abstract (Originalsprache)
Objective. This work proposes, for the first time, an image-based end-to-end self-normalization framework for positron emission tomography (PET) using conditional generative adversarial networks (cGANs). Approach. We evaluated different approaches by exploring each of the following three methodologies. First, we used images that were either unnormalized or corrected for geometric factors, which encompass all time-invariant factors, as input data types. Second, we set the input tensor shape as either a single axial slice (2D) or three contiguous axial slices (2.5D). Third, we chose either Pix2Pix or polarized self-attention (PSA) Pix2Pix, which we developed for this work, as a deep learning network. The targets for all approaches were the axial slices of images normalized using the direct normalization method. We performed Monte Carlo simulations of ten voxelized phantoms with the SimSET simulation tool and produced 26,000 pairs of axial image slices for training and testing. Main results. The results showed that 2.5D PSA Pix2Pix trained with geometric-factors-corrected input images achieved the best performance among all the methods we tested. All approaches improved general image quality figures of merit peak signal to noise ratio (PSNR) and structural similarity index (SSIM) from ∼15 % to ∼55 %, and 2.5D PSA Pix2Pix showed the highest PSNR (28.074) and SSIM (0.921). Lesion detectability, measured with region of interest (ROI) PSNR, SSIM, normalized contrast recovery coefficient, and contrast-to-noise ratio, was generally improved for all approaches, and 2.5D PSA Pix2Pix trained with geometric-factors-corrected input images achieved the highest ROI PSNR (28.920) and SSIM (0.973). Significance. This study demonstrates the potential of an image-based end-to-end self-normalization framework using cGANs for improving PET image quality and lesion detectability without the need for separate normalization scans.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America.
- Department of Radiology, Stanford University, Stanford, CA, United States of America.
- Department of Mechanical Engineering, Stanford University, Stanford, CA, United States of America.
- Department of Physics, Stanford University, Stanford, CA, United States of America.
- Department of Bioengineering, Stanford University, Stanford, CA, United States of America.
ORCID-Profile: Myungheon Chin, Mojtaba Jafaritadi
Förderung
- Emerson Collective Cancer Research Fund
- Wallace H Coulter Foundation
- Finnish Cultural Foundation
- Wallace H. Coulter Foundation
- Emerson Collective
- Suomen Kulttuurirahasto
Zitieren
APA
Chin, M., Jafaritadi, M., Franco, A. B., Nasir Ullah, M., Chinn, G., Innes, D., & Levin, C. S. (2024). Self-normalization for a 1 mm 3 resolution clinical PET system using deep learning. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ad69fb
Vancouver
Chin M, Jafaritadi M, Franco AB, Nasir Ullah M, Chinn G, Innes D, et al. Self-normalization for a 1 mm 3 resolution clinical PET system using deep learning. Physics in Medicine & Biology. 2024. doi:10.1088/1361-6560/ad69fb
BibTeX
@article{Chin2024,
author = {Chin, Myungheon and Jafaritadi, Mojtaba and Franco, Andrew B and Nasir Ullah, Muhammad and Chinn, Garry and Innes, Derek and Levin, Craig S},
title = {Self-normalization for a 1 mm 3 resolution clinical PET system using deep learning},
journal = {Physics in Medicine & Biology},
year = {2024},
doi = {10.1088/1361-6560/ad69fb}
}
EUVIMED