EUVIMEDEUVIMED entdecken
Crossref

Suppressing HIFU interference in ultrasound images using 1D U-Net-based neural networks

Kun Yang, Qiang Li, Hengxin Liu, Qingxuan Zeng, Dejia Cai, Jiahong Xu, Yingying Zhou, Po-Hsiang Tsui, Xiaowei Zhou

Physics in Medicine & Biology · 2024

DOI: 10.1088/1361-6560/ad2b95 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2024. Verfasst von Kun Yang und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Microelectronics, Tianjin University, Tianjin, People's Republic of China. Hauptthemen laut MEDLINE: Neural Networks, Computer, High-Intensity Focused Ultrasound Ablation. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Postgraduate Research Innovation Project of Tianjin, China, Tianjin Natural Science Foundation, Foundation of State Key Laboratory of Ultrasound in Medicine and Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. One big challenge with high-intensity focused ultrasound (HIFU) is that the intense acoustic interference generated by HIFU irradiation overwhelms the B-mode monitoring images, compromising monitoring effectiveness. This study aims to overcome this problem using a one-dimensional (1D) deep convolutional neural network. Approach . U-Net-based networks have been proven to be effective in image reconstruction and denoising, and the two-dimensional (2D) U-Net has already been investigated for suppressing HIFU interference in ultrasound monitoring images. In this study, we propose that the one-dimensional (1D) convolution in U-Net-based networks is more suitable for removing HIFU artifacts and can better recover the contaminated B-mode images compared to 2D convolution. Ex vivo and in vivo HIFU experiments were performed on a clinically equivalent ultrasound-guided HIFU platform to collect image data, and the 1D convolution in U-Net, Attention U-Net, U-Net++, and FUS-Net was applied to verify our proposal. Main results. All 1D U-Net-based networks were more effective in suppressing HIFU interference than their 2D counterparts, with over 30% improvement in terms of structural similarity (SSIM) to the uncontaminated B-mode images. Additionally, 1D U-Nets trained using ex vivo datasets demonstrated better generalization performance in in vivo experiments. Significance. These findings indicate that the utilization of 1D convolution in U-Net-based networks offers great potential in addressing the challenges of monitoring in ultrasound-guided HIFU systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neural Networks, ComputerHigh-Intensity Focused Ultrasound AblationUltrasonographyImage Processing, Computer-AssistedArtifacts

Stichwörter der Autor:innen

1D U-NetHIFU therapyUS-guide HIFUdeep learninghigh-intensity focused ultrasound (HIFU) interference

Autor:innen und Institutionen

  • School of Microelectronics, Tianjin University, Tianjin, People's Republic of China.
  • The State Key Laboratory of Ultrasound Engineering in Medicine, College of Biomedical Engineering, Chongqing Medical University, People's Republic of China.
  • Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
  • Division of Pediatric Gastroenterology, Department of Pediatrics, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan.
  • Research Center for Radiation Medicine, Chang Gung University, Taoyuan, Taiwan.

Förderung

  • Postgraduate Research Innovation Project of Tianjin, China
  • Tianjin Natural Science Foundation
  • Foundation of State Key Laboratory of Ultrasound in Medicine and Engineering
  • National Natural Science Foundation of China
  • Chang Gung Memorial Hospital, Taiwan
  • Natural Science Foundation of Tianjin Municipality
  • Chang Gung Memorial Hospital, Linkou
  • Tianjin Research Innovation Project for Postgraduate Students

Zitieren

APA

Yang, K., Li, Q., Liu, H., Zeng, Q., Cai, D., Xu, J., Zhou, Y., Tsui, P. H., & Zhou, X. (2024). Suppressing HIFU interference in ultrasound images using 1D U-Net-based neural networks. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ad2b95

Vancouver

Yang K, Li Q, Liu H, Zeng Q, Cai D, Xu J, et al. Suppressing HIFU interference in ultrasound images using 1D U-Net-based neural networks. Physics in Medicine & Biology. 2024. doi:10.1088/1361-6560/ad2b95

BibTeX
@article{Yang2024,
  author = {Yang, Kun and Li, Qiang and Liu, Hengxin and Zeng, Qingxuan and Cai, Dejia and Xu, Jiahong and Zhou, Yingying and Tsui, Po-Hsiang and Zhou, Xiaowei},
  title = {Suppressing HIFU interference in ultrasound images using 1D U-Net-based neural networks},
  journal = {Physics in Medicine & Biology},
  year = {2024},
  doi = {10.1088/1361-6560/ad2b95}
}
Kostenlos starten →