Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2023. Verfasst von A Smolders und 7 weiteren Autor:innen. Beteiligte Einrichtung: Paul Scherrer Institute, Center for Proton Therapy, Switzerland. Hauptthemen laut MEDLINE: Proton Therapy. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 Marie Skłodowska-Curie Actions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow. Whereas multiple methods for autocontouring exist, none of them are fully accurate, which affects the daily dose. This work aims to quantify the magnitude of this dosimetric effect for four contouring techniques. Approach. Plans reoptimized on automatic contours are compared with plans reoptimized on manual contours. The methods include rigid and deformable registration (DIR), deep-learning based segmentation and patient-specific segmentation. Main results. It was found that independently of the contouring method, the dosimetric influence of using automatic OAR contours is small (5% prescribed dose in most cases), indicating that manual verification of that contour remains necessary. However, when compared to non-adaptive therapy, the dose differences caused by automatically contouring the target were small and target coverage was improved, especially for DIR. Significance. The results show that manual adjustment of OARs is rarely necessary and that several autocontouring techniques are directly usable. Contrarily, manual adjustment of the target is important. This allows prioritizing tasks during time-critical online adaptive proton therapy and therefore supports its further clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Proton TherapyHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedImage Processing, Computer-AssistedRadiometryOrgans at Risk

Stichwörter der Autor:innen

adaptive radiotherapycontour propagationdeformable image registrationhead and neck cancerlung cancerproton therapy

Autor:innen und Institutionen

  • Paul Scherrer Institute, Center for Proton Therapy, Switzerland.
  • Department of Physics, ETH Zurich, Switzerland.
  • Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Switzerland.
  • Department of Radiation Oncology, University Hospital Zurich, Switzerland.

ORCID-Profile: A Smolders

Förderung

  • H2020 Marie Skłodowska-Curie Actions

Zitieren

APA

Smolders, A., Choulilitsa, E., Czerska, K., Bizzocchi, N., Krcek, R., Lomax, A., Weber, D. C., & Albertini, F. (2023). Dosimetric comparison of autocontouring techniques for online adaptive proton therapy. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/ace307

Vancouver

Smolders A, Choulilitsa E, Czerska K, Bizzocchi N, Krcek R, Lomax A, et al. Dosimetric comparison of autocontouring techniques for online adaptive proton therapy. Physics in Medicine & Biology. 2023. doi:10.1088/1361-6560/ace307

BibTeX
@article{Smolders2023,
  author = {Smolders, A and Choulilitsa, E and Czerska, K and Bizzocchi, N and Krcek, R and Lomax, A and Weber, D C and Albertini, F},
  title = {Dosimetric comparison of autocontouring techniques for online adaptive proton therapy},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  doi = {10.1088/1361-6560/ace307}
}
Kostenlos starten →