EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network

Mahdieh Dashtbani Moghari, Amirhossein Sanaat, Noel Young, Krystal Moore, Habib Zaidi iD, Andrew Evans, Roger R Fulton iD, Andre Z Kyme iD

Physics in Medicine & Biology · 2023

DOI: 10.1088/1361-6560/acdf3a ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, 2023. Verfasst von Mahdieh Dashtbani Moghari und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Faculty of Engineering and Information Technologies, The University of Sydney, Sydney, Australia. Hauptthemen laut MEDLINE: Stroke, Brain Ischemia. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Cerebral CT perfusion (CTP) imaging is most commonly used to diagnose acute ischaemic stroke and support treatment decisions. Shortening CTP scan duration is desirable to reduce the accumulated radiation dose and the risk of patient head movement. In this study, we present a novel application of a stochastic adversarial video prediction approach to reduce CTP imaging acquisition time. Approach . A variational autoencoder and generative adversarial network (VAE-GAN) were implemented in a recurrent framework in three scenarios: to predict the last 8 (24 s), 13 (31.5 s) and 18 (39 s) image frames of the CTP acquisition from the first 25 (36 s), 20 (28.5 s) and 15 (21 s) acquired frames, respectively. The model was trained using 65 stroke cases and tested on 10 unseen cases. Predicted frames were assessed against ground-truth in terms of image quality and haemodynamic maps, bolus shape characteristics and volumetric analysis of lesions. Main results . In all three prediction scenarios, the mean percentage error between the area, full-width-at-half-maximum and maximum enhancement of the predicted and ground-truth bolus curve was less than 4 ± 4%. The best peak signal-to-noise ratio and structural similarity of predicted haemodynamic maps was obtained for cerebral blood volume followed (in order) by cerebral blood flow, mean transit time and time to peak. For the 3 prediction scenarios, average volumetric error of the lesion was overestimated by 7%–15%, 11%–28% and 7%–22% for the infarct, penumbra and hypo-perfused regions, respectively, and the corresponding spatial agreement for these regions was 67%–76%, 76%–86% and 83%–92%. Significance . This study suggests that a recurrent VAE-GAN could potentially be used to predict a portion of CTP frames from truncated acquisitions, preserving the majority of clinical content in the images, and potentially reducing the scan duration and radiation dose simultaneously by 65% and 54.5%, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrokeBrain IschemiaHumansTomography, X-Ray ComputedNeural Networks, ComputerPerfusion ImagingCerebrovascular CirculationRadiation Dosage

Stichwörter der Autor:innen

CT perfusion imagingacute ischaemic strokedeep learningradiation dose reductionscan duration reduction

Autor:innen und Institutionen

  • School of Biomedical Engineering, Faculty of Engineering and Information Technologies, The University of Sydney, Sydney, Australia.
  • Geneva University Hospitals, Division of Nuclear Medicine & Molecular Imaging, CH-1205 Geneva, Switzerland.
  • Department of Radiology, Westmead Hospital, Sydney, Australia.
  • Medical imaging group, School of Medicine, Western Sydney University, Sydney, Australia.
  • Department of Aged Care & Stroke, Westmead Hospital, Sydney, Australia.
  • School of Health Sciences, University of Sydney, Sydney, Australia.

ORCID-Profile: Habib Zaidi, Roger R Fulton, Andre Z Kyme

Zitieren

APA

Dashtbani Moghari, M., Sanaat, A., Young, N., Moore, K., Zaidi, H., Evans, A., Fulton, R. R., & Kyme, A. Z. (2023). Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network. Physics in Medicine & Biology. https://doi.org/10.1088/1361-6560/acdf3a

Vancouver

Dashtbani Moghari M, Sanaat A, Young N, Moore K, Zaidi H, Evans A, et al. Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network. Physics in Medicine & Biology. 2023. doi:10.1088/1361-6560/acdf3a

BibTeX
@article{DashtbaniMoghari2023,
  author = {Dashtbani Moghari, Mahdieh and Sanaat, Amirhossein and Young, Noel and Moore, Krystal and Zaidi, Habib and Evans, Andrew and Fulton, Roger R and Kyme, Andre Z},
  title = {Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  doi = {10.1088/1361-6560/acdf3a}
}
Kostenlos starten →