EUVIMEDEUVIMED entdecken
Crossref

Physics-informed sinogram completion for metal artifact reduction in CT imaging

Manman Zhu, Qisen Zhu, Yuyan Song, Yi Guo iD, Dong Zeng, Zhaoying Bian iD, Yongbo Wang, Jianhua Ma iD

Physics in Medicine & Biology · 21.03.2023 · 68 (6) · 065006

DOI: 10.1088/1361-6560/acbddf ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics in Medicine & Biology, online erschienen am 13.03.2023. Verfasst von Manman Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China. Hauptthemen laut MEDLINE: Artifacts, Tomography, X-Ray Computed. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key R&D Program of China, Science and Technology Program of Guangzhou, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Metal artifacts in the computed tomography (CT) imaging are unavoidably adverse to the clinical diagnosis and treatment outcomes. Most metal artifact reduction (MAR) methods easily result in the over-smoothing problem and loss of structure details near the metal implants, especially for these metal implants with irregular elongated shapes. To address this problem, we present the physics-informed sinogram completion (PISC) method for MAR in CT imaging, to reduce metal artifacts and recover more structural textures. Approach. Specifically, the original uncorrected sinogram is firstly completed by the normalized linear interpolation algorithm to reduce metal artifacts. Simultaneously, the uncorrected sinogram is also corrected based on the beam-hardening correction physical model, to recover the latent structure information in metal trajectory region by leveraging the attenuation characteristics of different materials. Both corrected sinograms are fused with the pixel-wise adaptive weights, which are manually designed according to the shape and material information of metal implants. To furtherly reduce artifacts and improve the CT image quality, a post-processing frequency split algorithm is adopted to yield the final corrected CT image after reconstructing the fused sinogram. Main results. We qualitatively and quantitatively evaluated the presented PISC method on two simulated datasets and three real datasets. All results demonstrate that the presented PISC method can effectively correct the metal implants with various shapes and materials, in terms of artifact suppression and structure preservation. Significance. We proposed a sinogram-domain MAR method to compensate for the over-smoothing problem existing in most MAR methods by taking advantage of the physical prior knowledge, which has the potential to improve the performance of the deep learning based MAR approaches.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsTomography, X-Ray ComputedAlgorithmsMetalsPhysicsPhantoms, ImagingImage Processing, Computer-Assisted

Stichwörter der Autor:innen

computed tomographymetal artifacts reductionphysical correctionsinogram completion

Substanzen

Metals

Autor:innen und Institutionen

  • School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China.
  • Pazhou Lab (Huangpu), Guangzhou 510700, People's Republic of China.

ORCID-Profile: Yi Guo, Zhaoying Bian, Jianhua Ma

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Program of China
  • Science and Technology Program of Guangzhou, China
  • China Postdoctoral Science Foundation

Zitieren

APA

Zhu, M., Zhu, Q., Song, Y., Guo, Y., Zeng, D., Bian, Z., Wang, Y., & Ma, J. (2023). Physics-informed sinogram completion for metal artifact reduction in CT imaging. Physics in Medicine & Biology, 68(6), 065006. https://doi.org/10.1088/1361-6560/acbddf

Vancouver

Zhu M, Zhu Q, Song Y, Guo Y, Zeng D, Bian Z, et al. Physics-informed sinogram completion for metal artifact reduction in CT imaging. Physics in Medicine & Biology. 2023;68(6):065006. doi:10.1088/1361-6560/acbddf

BibTeX
@article{Zhu2023,
  author = {Zhu, Manman and Zhu, Qisen and Song, Yuyan and Guo, Yi and Zeng, Dong and Bian, Zhaoying and Wang, Yongbo and Ma, Jianhua},
  title = {Physics-informed sinogram completion for metal artifact reduction in CT imaging},
  journal = {Physics in Medicine & Biology},
  year = {2023},
  volume = {68},
  number = {6},
  pages = {065006},
  doi = {10.1088/1361-6560/acbddf}
}
Kostenlos starten →