EUVIMEDEUVIMED entdecken
Crossref

Measurement Validation as Scientific Claim Admissibility: An Evidence-Gated Decision Framework

BENAISSA Mohamed, Foued DERRAZ, Sidi Mohammed CHORFI

Measurement Science and Technology · 11.11.2026

DOI: 10.1088/1361-6501/aec0c0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 11.11.2026. Verfasst von BENAISSA Mohamed und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurement validation is often reported as a binary property of an instrument, although a single system may support some bounded conclusions while leaving stronger ones unsupported. This paper formulates validation as a constrained scientific claim-admissibility problem. A general operator maps declared intended use, evaluated evidence, claim-specific requirements and claim strength to admitted and maximal claims, blocked overclaims, retained limitations, abstentions and next evidence actions. The Evidence-Gated Decision Framework implements this operator through applicability resolution, strict non-compensation and a versioned audit trace. Formal consistency properties establish monotonicity, irredundant evidence bases and local degradation under evidence removal for a frozen model. Measurement uncertainty, traceability and JCGM 106-type conformity decisions remain locally evaluated evidence objects. A synthetic temperature demonstrator isolates the decision logic, while an independent real-data motor-vibration case adds practical evaluation using 24 OROS OR35 acquisitions at four rotational-speed conditions. A magnetically mounted Dytran 3214A2 accelerometer and a Monarch ROS optical tachometer are acquired on the same time base. Across 600, 800, 1000 and 1200 min−1, the absolute group-mean vibration-derived 1×/tachometer frequency differences range from 1.94 × 10−4 to 5.92 × 10−4 Hz, the maximum absolute record-level difference is 0.002408 Hz, and the expanded comparison uncertainties are about 0.0096 Hz (k = 2). The case shows how one local compatibility result supports a bounded frequency-consistency claim without implying traceable acceleration, universal spectral interpretation or field readiness. Seven claim-separable evidence classes are instantiated as EVL 0–6, with EVL 7 reserved for the adjudicated output.

Zitieren

APA

Mohamed, B., DERRAZ, F., & CHORFI, S. M. (2026). Measurement Validation as Scientific Claim Admissibility: An Evidence-Gated Decision Framework. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aec0c0

Vancouver

Mohamed B, DERRAZ F, CHORFI SM. Measurement Validation as Scientific Claim Admissibility: An Evidence-Gated Decision Framework. Measurement Science and Technology. 2026. doi:10.1088/1361-6501/aec0c0

BibTeX
@article{Mohamed2026,
  author = {Mohamed, BENAISSA and DERRAZ, Foued and CHORFI, Sidi Mohammed},
  title = {Measurement Validation as Scientific Claim Admissibility: An Evidence-Gated Decision Framework},
  journal = {Measurement Science and Technology},
  year = {2026},
  doi = {10.1088/1361-6501/aec0c0}
}
Kostenlos starten →