EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Continuous UV level estimation using photochromic PLA surfaces: A transformer-based heterogeneous deep ensemble approach

Eşref Erdoğan, Serkan Keser, Sekip Esat HAYBER, Omer Galip Saracoglu

Measurement Science and Technology · 09.11.2026

DOI: 10.1088/1361-6501/aebfbc ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 09.11.2026. Verfasst von Eşref Erdoğan und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Fund of Bursa Uludağ University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a high-precision, continuous machine vision system for estimating ultraviolet (UV) radiation levels using low-cost, 3D-printable polylactic acid-based photochromic material (PLA-PCM) surfaces. Filament color transitions under different UV intensities were recorded at eight ambient color temperatures, and a zero-padding spatial arrangement protocol was applied to the 252×56 images that underwent color changes to extract stable temporal features. The methodology employs a deep transformer encoder (DTE) with multi-head self-attention (MSA), computing global temporal dependencies in parallel within 222 milliseconds and ensuring edge-AI compatibility. Multi-spectral feature vectors from the RGB, HSV, and CIELAB color spaces, augmented with ambient color temperature and DCT components, were constructed for 59,000 frames derived from 236 video sessions at 10 Hz. A strict zero-data-leakage protocol was enforced through video-level holdout and stratified temporal splits. Each fold equally represented the fast-onset and slow-decay phases of the photochromic reaction within a five-fold cross-validation. The resulting transformer-based heterogeneous deep ensemble (T-HDE), integrating Transformer, SVR, CatBoost, LightGBM, ExtraTrees, and MLP regressors with Nelder-Mead optimized weights, achieved R 2 = 0.9938 on the held-out test set with a homoscedastic error distribution, indicating that prediction accuracy remains equally reliable across low and high UV exposure levels. In single-frame snapshot mode, R 2 = 0.9811 was attained, confirming that even without temporal sequence information, the zero-padding-based spatial features alone provide robust UV estimation. These findings demonstrate that PLA-PCM surfaces, coupled with the T-HDE architecture, can serve as precise, continuous, and cost-effective UV dosimeters for IoT-based environmental monitoring and edge-AI sensing platforms.

Förderung

  • Research Fund of Bursa Uludağ University

Zitieren

APA

Erdoğan, E., Keser, S., HAYBER, S. E., & Saracoglu, O. G. (2026). Continuous UV level estimation using photochromic PLA surfaces: A transformer-based heterogeneous deep ensemble approach. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aebfbc

Vancouver

Erdoğan E, Keser S, HAYBER SE, Saracoglu OG. Continuous UV level estimation using photochromic PLA surfaces: A transformer-based heterogeneous deep ensemble approach. Measurement Science and Technology. 2026. doi:10.1088/1361-6501/aebfbc

BibTeX
@article{Erdoan2026,
  author = {Erdoğan, Eşref and Keser, Serkan and HAYBER, Sekip Esat and Saracoglu, Omer Galip},
  title = {Continuous UV level estimation using photochromic PLA surfaces: A transformer-based heterogeneous deep ensemble approach},
  journal = {Measurement Science and Technology},
  year = {2026},
  doi = {10.1088/1361-6501/aebfbc}
}
Kostenlos starten →