Signal decomposition methods for non-contact vital-sign extraction using stepped-frequency continuous-wave radar
Measurement Science and Technology · 20.11.2026 · 37 (46) · 466103
DOI: 10.1088/1361-6501/aebd0e ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 19.11.2026. Verfasst von Piyush K Mathurkar und 1 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Non-contact methods that accurately estimate heart and respiration rates are an important goal in radar-based vital sign measurement that can be used for health surveillance without intrusion, sleep monitoring, and medical scenarios where contact sensors are not feasible. This paper conducts a comparative study of three signal decomposition techniques—empirical mode decomposition (EMD), ensemble empirical mode decomposition (EEMD), and variational mode decomposition (VMD)—for simultaneous estimation of cardiac and respiratory rates from stepped-frequency continuous-wave radar signals. The radar echo was processed by coherently averaging the range bins covering the subject’s chest to form respiratory and cardiac displacement signals that were decomposed into intrinsic mode functions. The dominant physiological mode in each target band (0.10–0.50 Hz for respiration, 0.80–2.00 Hz for the cardiac component) was selected by the in-band signal-to-noise ratio (SNR) with spectral entropy as the descriptor of spectral compactness. The signal processing pipeline was evaluated on two subjects at rest. The three methods agreed closely, with the respiratory rate and heart rate for Subject 1 being 18.8 breaths min –1 and 66.8 beats min −1 , respectively, and 14.4 breaths min –1 and 76.5 beats min −1 for Subject 2. VMD achieved the highest in-band SNR in both channels (23.89 dB for respiratory, 12.21 dB for cardiac), exceeding EMD and EEMD by 7 dB and 4.5 dB, with the lowest spectral entropy (0.215 and 0.457, a 29%–38% reduction). VMD also required only four modes versus five or six for the others, simplifying selection and improving reproducibility. Validation of the signal processing pipeline was done using a 1.5 Hz mechanical oscillating machine, which yielded a 1.33% relative error; a measurement uncertainty analysis (coverage factor k = 2) established the reported rate as 18.8 ± 0.7 breaths min –1 and 66.8 ± 1.2 beats min −1 for Subject 1, and 14.4 ± 0.7 breaths min –1 and 76.5 ± 1.2 beats min −1 for Subject 2.
Zitieren
APA
Mathurkar, P. K., & Gaikwad, A. N. (2026). Signal decomposition methods for non-contact vital-sign extraction using stepped-frequency continuous-wave radar. Measurement Science and Technology, 37(46), 466103. https://doi.org/10.1088/1361-6501/aebd0e
Vancouver
Mathurkar PK, Gaikwad AN. Signal decomposition methods for non-contact vital-sign extraction using stepped-frequency continuous-wave radar. Measurement Science and Technology. 2026;37(46):466103. doi:10.1088/1361-6501/aebd0e
BibTeX
@article{Mathurkar2026,
author = {Mathurkar, Piyush K and Gaikwad, Abhay N},
title = {Signal decomposition methods for non-contact vital-sign extraction using stepped-frequency continuous-wave radar},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {46},
pages = {466103},
doi = {10.1088/1361-6501/aebd0e}
}
EUVIMED