EUVIMEDEUVIMED entdecken
Crossref

Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography

Jeonggeun Song, Jinsu Choi, Soonyong Kwon, Won Seok Chang, Hongki Yoo

Measurement Science and Technology · 13.11.2026 · 37 (45) · 455201

DOI: 10.1088/1361-6501/aebd04 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 12.11.2026. Verfasst von Jeonggeun Song und 4 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Korea Ministry of Trade, Industry & Energy, National Research Foundation of Korea, Basic Research Fund of the Korea Institute of Machinery and Materials.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nondestructive, post-exposure monitoring of latent photoresist patterns remains challenging because conventional metrology relies on post-development inspection, making it difficult to attribute deviations to exposure conditions. We propose an autofluorescence-imaging-based monitoring method that operates immediately after ultraviolet exposure, using excitation wavelengths spectrally separated from the exposure wavelength, and establish its performance as a measurement. To identify a suitable monitoring wavelength, latent patterns were imaged at four excitation wavelengths. Among the wavelengths tested, 561 nm provided the most stable latent-pattern signal, with only a −3.1% change after 30 s of continuous excitation, whereas shorter-wavelength excitation caused unintended additional exposure or substantial photobleaching. The autofluorescence contrast increased nonlinearly with exposure dose and gradually approached saturation, as described by a model derived from depth-integrated photochemical conversion. Inverting the fitted response estimated the delivered dose with 6%–11% RMS error (leave-one-out), and retained sensitivity above the dose to clear, where the developed topography saturated and post-development inspection became insensitive to over-dose. In two independently conducted exposure experiments, no systematic monitoring-induced change in the developed geometry was detected, and the minimum detectable dose was 9.7 mJ cm −2 at 3σ. This label-free approach enables pre-development latent-pattern imaging and quantitative dose monitoring for microscale maskless lithography and process development.

Förderung

  • Korea Ministry of Trade, Industry & Energy
  • National Research Foundation of Korea
  • Basic Research Fund of the Korea Institute of Machinery and Materials

Zitieren

APA

Song, J., Choi, J., Kwon, S., Chang, W. S., & Yoo, H. (2026). Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography. Measurement Science and Technology, 37(45), 455201. https://doi.org/10.1088/1361-6501/aebd04

Vancouver

Song J, Choi J, Kwon S, Chang WS, Yoo H. Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography. Measurement Science and Technology. 2026;37(45):455201. doi:10.1088/1361-6501/aebd04

BibTeX
@article{Song2026,
  author = {Song, Jeonggeun and Choi, Jinsu and Kwon, Soonyong and Chang, Won Seok and Yoo, Hongki},
  title = {Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {45},
  pages = {455201},
  doi = {10.1088/1361-6501/aebd04}
}
Kostenlos starten →