A simple and robust balanced homodyne detector for high-repetition-rate pulsed sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi, Sebastiano Corli, ENRICO PRATI, Simone Cialdi

Measurement Science and Technology · 03.11.2026

DOI: 10.1088/1361-6501/aebd03 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 03.11.2026. Verfasst von Samuele Altilia und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: INFN CSN5.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-topulse correlations is developed, providing quantitative predictions for the signal variance, signal-tonoise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust, simple and reproducible solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

Förderung

  • INFN CSN5

Zitieren

APA

Altilia, S., Suerra, E., Puppi, P., Corli, S., PRATI, E., & Cialdi, S. (2026). A simple and robust balanced homodyne detector for high-repetition-rate pulsed sources. Measurement Science and Technology. https://doi.org/10.1088/1361-6501/aebd03

Vancouver

Altilia S, Suerra E, Puppi P, Corli S, PRATI E, Cialdi S. A simple and robust balanced homodyne detector for high-repetition-rate pulsed sources. Measurement Science and Technology. 2026. doi:10.1088/1361-6501/aebd03

BibTeX
@article{Altilia2026,
  author = {Altilia, Samuele and Suerra, Edoardo and Puppi, Pietro and Corli, Sebastiano and PRATI, ENRICO and Cialdi, Simone},
  title = {A simple and robust balanced homodyne detector for high-repetition-rate pulsed sources},
  journal = {Measurement Science and Technology},
  year = {2026},
  doi = {10.1088/1361-6501/aebd03}
}
Kostenlos starten →