Extraction of rotor unbalance characteristics from non-stationary vibration signals during speed fluctuations
Measurement Science and Technology · 06.11.2026 · 37 (44) · 445004
DOI: 10.1088/1361-6501/aeb968 ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 06.11.2026. Verfasst von Hui Qian und 8 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Speed fluctuations introduce pronounced non-stationarity into rotor vibration signals, which makes the accurate extraction of rotational-frequency, amplitude, and phase characteristics considerably more difficult than under steady-speed conditions. To address this problem, a rotor-unbalance characteristic-extraction method is developed for speed-fluctuation conditions. The procedure first evaluates supervised normalized least mean square (NLMS) filtering followed by fixed forward–backward zero-phase filtering for noise suppression without additional phase distortion. The multisynchrosqueezing transform (MSST) is then applied to improve time–frequency energy concentration and track the instantaneous rotational-frequency component of the non-stationary vibration signal. The instantaneous phase is subsequently resampled using the keyphasor signal, and phase tracking regression (PTR) is applied to estimate the rotational-frequency phase under speed fluctuation and keyphasor jitter. Simulation results show that the combined NLMS and zero-phase filtering method achieves the highest output signal-to-noise ratio and the lowest root mean square error among the compared filtering methods. MSST provides better time–frequency energy concentration than the other investigated time–frequency methods, while PTR maintains relatively stable phase-estimation performance under variations in noise level, keyphasor jitter, frequency modulation ratio, and sampling duration. Experiments on the investigated three-disk rotor further show that PTR yields a phase standard deviation of 4.363° across the segmented steady-state measurements, and the vibration amplitudes at all three measurement locations are reduced by more than 70% in both balancing tests at 5000 rpm, demonstrating the effectiveness of the proposed method for the present rotor configuration and tested operating condition.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Qian, H., Huang, B., Liu, Q., Tang, Z., Tang, Y., Wang, Y., Zhang, C., Miao, X., & Jiang, D. (2026). Extraction of rotor unbalance characteristics from non-stationary vibration signals during speed fluctuations. Measurement Science and Technology, 37(44), 445004. https://doi.org/10.1088/1361-6501/aeb968
Vancouver
Qian H, Huang B, Liu Q, Tang Z, Tang Y, Wang Y, et al. Extraction of rotor unbalance characteristics from non-stationary vibration signals during speed fluctuations. Measurement Science and Technology. 2026;37(44):445004. doi:10.1088/1361-6501/aeb968
BibTeX
@article{Qian2026,
author = {Qian, Hui and Huang, Bokai and Liu, Qinghua and Tang, Zhenhuan and Tang, Yong and Wang, Yusheng and Zhang, Chao and Miao, Xueyang and Jiang, Dong},
title = {Extraction of rotor unbalance characteristics from non-stationary vibration signals during speed fluctuations},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {44},
pages = {445004},
doi = {10.1088/1361-6501/aeb968}
}
EUVIMED