EUVIMEDEUVIMED entdecken
Crossref

Mechanism analysis and compensation method for tilt-induced error in chromatic confocal thickness measurement of transparent media

Xiali Liu, Yaohua Deng

Measurement Science and Technology · 13.11.2026 · 37 (45) · 455004

DOI: 10.1088/1361-6501/aeb8a5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 11.11.2026. Verfasst von Xiali Liu und 1 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Guangdong Science and Technology Plan Project, Dongguan Key Research and Development Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chromatic confocal sensing provides a noncontact approach for thickness measurement of transparent media with multiple interfaces. In practice, however, unavoidable sample tilt causes simultaneous degradation of return-signal coupling and spectral response, which leads to significant thickness errors. In this work, the error formation pathway from tilt to spectral distortion and finally to thickness deviation is systematically investigated, and a compensation method is proposed. First, based on the weighted superposition of entrance-pupil energy contributions, the effects of tilt-induced off-axis return and off-axis dispersion-mapping variation on spectral peak position and profile stability are analyzed. A Zemax non-sequential ray tracing model is then established to quantify the evolution of the two-dimensional irradiance distribution, return power, and dual-interface spectral features under different tilt angles. The results show that stable dual-interface responses can still be maintained at small tilts, whereas beyond a critical tilt range the system exhibits rapid coupling loss and reduced peak separability. Experimental measurements using a CL3-MG70 probe and transparent quartz plates further confirm the simulation trends and show that the tilt-induced thickness error increases approximately in proportion to the sample thickness. On this basis, a unified magnification model is established for the investigated probe and quartz samples and applied to tilt-error compensation. Using the thickness deviation relative to the 0° condition as the evaluation metric, the proposed method reduces both the maximum drift E max and root-mean-square error by more than 90%, demonstrating a substantial improvement in measurement stability. These results provide a practical reference for tilt error analysis and correction in chromatic confocal thickness measurement of rigid transparent plates.

Förderung

  • Guangdong Science and Technology Plan Project
  • Dongguan Key Research and Development Project

Zitieren

APA

Liu, X., & Deng, Y. (2026). Mechanism analysis and compensation method for tilt-induced error in chromatic confocal thickness measurement of transparent media. Measurement Science and Technology, 37(45), 455004. https://doi.org/10.1088/1361-6501/aeb8a5

Vancouver

Liu X, Deng Y. Mechanism analysis and compensation method for tilt-induced error in chromatic confocal thickness measurement of transparent media. Measurement Science and Technology. 2026;37(45):455004. doi:10.1088/1361-6501/aeb8a5

BibTeX
@article{Liu2026,
  author = {Liu, Xiali and Deng, Yaohua},
  title = {Mechanism analysis and compensation method for tilt-induced error in chromatic confocal thickness measurement of transparent media},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {45},
  pages = {455004},
  doi = {10.1088/1361-6501/aeb8a5}
}
Kostenlos starten →