EUVIMEDEUVIMED entdecken
Crossref

Temperature-induced Rb–Xe coupling error modeling and analysis in NMR sensors

Junjie Zhang, Xuelie Wang, Hao Tian, Hanyu Wang, Jianli Li, Zhanchao Liu

Measurement Science and Technology · 13.11.2026 · 37 (45) · 455103

DOI: 10.1088/1361-6501/aeb718 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 09.11.2026. Verfasst von Junjie Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Science Fund, Quantum Science and Technology-National Science and Technology Major Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Temperature-induced Rb–Xe coupling error is a critical factor limiting the accuracy of miniaturized nuclear magnetic resonance (NMR) sensors. In this work, a temperature-dependent theoretical model is developed to describe how vapor cell temperature affects the output phase of Xe isotope signals through the in-situ Rb atomic magnetometer and the signal-processing loop. Based on the Bloch equation and demodulation process, the model reveals that temperature variations modify both the magnetic field sensed by Rb atoms and the transverse relaxation time of Rb atoms, thereby producing phase errors in the measured Xe precession signal. Numerical simulations further show that the amplitude and phase of the Xe signal are sensitive to Rb spin-frequency detuning and relaxation-time variation, and that the coupling-induced phase shift becomes more significant at higher Xe spin frequencies. Experiments were performed by measuring the temperature dependences of the light-shift equivalent magnetic field, nuclear-spin equivalent magnetic field, and Rb transverse relaxation time, which were then incorporated into the theoretical model. The calculated phase shifts agree well with the measured results for both 129 Xe and 131 Xe, with R-squared values of 0.9910 and 0.9931, respectively. These results verify the proposed model and demonstrate that temperature-driven variations in Rb-related parameters are the dominant source of Rb–Xe coupling phase error. This study clarifies the temperature-dependent error mechanism in NMR sensors and provides a theoretical basis for improving their long-term accuracy and environmental robustness.

Förderung

  • National Science Fund
  • Quantum Science and Technology-National Science and Technology Major Project

Zitieren

APA

Zhang, J., Wang, X., Tian, H., Wang, H., Li, J., & Liu, Z. (2026). Temperature-induced Rb–Xe coupling error modeling and analysis in NMR sensors. Measurement Science and Technology, 37(45), 455103. https://doi.org/10.1088/1361-6501/aeb718

Vancouver

Zhang J, Wang X, Tian H, Wang H, Li J, Liu Z. Temperature-induced Rb–Xe coupling error modeling and analysis in NMR sensors. Measurement Science and Technology. 2026;37(45):455103. doi:10.1088/1361-6501/aeb718

BibTeX
@article{Zhang2026,
  author = {Zhang, Junjie and Wang, Xuelie and Tian, Hao and Wang, Hanyu and Li, Jianli and Liu, Zhanchao},
  title = {Temperature-induced Rb–Xe coupling error modeling and analysis in NMR sensors},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {45},
  pages = {455103},
  doi = {10.1088/1361-6501/aeb718}
}
Kostenlos starten →