Assessing and mitigating the impact of fluorescence and camera non-linearity on accurate 2D surface phosphor thermometry
Measurement Science and Technology · 13.11.2026 · 37 (45) · 455202
DOI: 10.1088/1361-6501/aeb4d9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 13.11.2026. Verfasst von Anthony O Ojo und 4 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPSRC.
Abstract (Originalsprache)
Accurate knowledge of temperature is fundamental to understanding heat transfer processes in many applications. Phosphor thermometry (PT) has significantly advanced this understanding by enabling remote temperature measurements. The accuracy of PT measurements is often limited by the accuracy of the reference (e.g. thermocouple; < ±2.5 °C accuracy) used for PT calibration. In practice, challenging applications can exhibit unique features that are absent in the calibration environment, and these features can impact PT accuracy. This study focuses on surface temperature ( T surface ) measurements in a flame spread application which presents some attributes not accounted for during PT calibration. By measuring T surface during flame spread over polymethyl methacrylate (PMMA) samples coated with thermographic phosphor particles, this paper examines how specific attributes of the application—PMMA fluorescence and thermal decomposition—affect measurement accuracy. Two-dimensional T surface measurements are performed using a lifetime-based intensity ratio approach that exploits the intensities of images captured by a CMOS camera during the phosphorescence decay of Gd 3 Ga 5 O 12 :Cr,Ce. Chemiluminescence (CH*) imaging, performed simultaneously with T surface measurements, tracks flame progression during flame spread. The accuracy of 2D T surface measurements is investigated relative to single-point (0-D) T surface measurements conducted with thermocouples and with PT (using a photomultiplier tube (PMT) as the detector). Findings reveal how the 2D T surface measurements, especially from the burning surface, can be impacted by fluorescence and the camera’s non‐linear response to phosphorescence changes during PMMA decomposition. 0-D T surface measurements, enabled by a PMT offering better linearity, revealed that deviation of these 2D T surface measurements can be as high as 120 °C. Mitigation strategies, involving time-gating and the isolation of images prone to non-linearities, were implemented thereby improving the measurement accuracy (∼ 6.5 °C mean deviation) of the 2D T surface on the burning surface. The findings here can benefit other applications where the underlying physical processes induce variations that are non-existent during PT calibration.
Förderung
- EPSRC
Zitieren
APA
Ojo, A. O., Morrisset, D., Padhiary, A., Hadden, R. M., & Peterson, B. (2026). Assessing and mitigating the impact of fluorescence and camera non-linearity on accurate 2D surface phosphor thermometry. Measurement Science and Technology, 37(45), 455202. https://doi.org/10.1088/1361-6501/aeb4d9
Vancouver
Ojo AO, Morrisset D, Padhiary A, Hadden RM, Peterson B. Assessing and mitigating the impact of fluorescence and camera non-linearity on accurate 2D surface phosphor thermometry. Measurement Science and Technology. 2026;37(45):455202. doi:10.1088/1361-6501/aeb4d9
BibTeX
@article{Ojo2026,
author = {Ojo, Anthony O and Morrisset, David and Padhiary, Abhijit and Hadden, Rory M and Peterson, Brian},
title = {Assessing and mitigating the impact of fluorescence and camera non-linearity on accurate 2D surface phosphor thermometry},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {45},
pages = {455202},
doi = {10.1088/1361-6501/aeb4d9}
}