EUVIMEDEUVIMED entdecken
Crossref

TF-Former: a concentration regression model for toxic and harmful mixed gases based on time-frequency analysis

Xinyu Zhang, Songqi Gao, Xiaoran Huang, Peter Feng, Jin Chu

Measurement Science and Technology · 13.11.2026 · 37 (45) · 455107

DOI: 10.1088/1361-6501/aeb3a0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 13.11.2026. Verfasst von Xinyu Zhang und 4 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Gefördert von: Graduate Research and Innovation Foundation of Southwest University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate quantification of individual components in mixed gases remains challenging for metal oxide (MOX) electronic noses because cross-sensitivity can produce highly overlapping sensor responses. In this study, we propose TF-Former, a time–frequency Transformer framework for the simultaneous regression of carbon monoxide (CO) and ethylene (C 2 H 4 ) concentrations from multichannel MOX sensor signals. For the public UCI dynamic gas-mixture dataset, electrical responses from 16 chemiresistive sensors were acquired at 100 Hz under a constant heater voltage of 5 V. The signals were downsampled to 1 Hz, standardized using statistics estimated from the training data only, and grouped by continuous constant-concentration exposure intervals to reduce information leakage across the training, validation, and test subsets. TF-Former jointly encodes the original time-domain sequence and single-level Haar discrete wavelet transform coefficients, and integrates the two representations through bidirectional cross-domain attention before concentration regression. Across five random seeds, TF-Former achieved R 2 values of 0.9960 ± 0.0019 for CO and 0.9931 ± 0.0021 for C 2 H 4 on the grouped UCI evaluation. On a second MOX-array dataset evaluated using held-out concentration combinations, TF-Former achieved R 2 values of 0.9877 ± 0.0101 for CO and 0.9886 ± 0.0093 for C 2 H 4 . Additional Gaussian-noise perturbation experiments were conducted to assess prediction stability under corrupted inputs. These results demonstrate the potential of joint time-frequency representation learning for concentration estimation of known CO/C 2 H 4 mixtures under the investigated conditions.

Förderung

  • Graduate Research and Innovation Foundation of Southwest University

Zitieren

APA

Zhang, X., Gao, S., Huang, X., Feng, P., & Chu, J. (2026). TF-Former: a concentration regression model for toxic and harmful mixed gases based on time-frequency analysis. Measurement Science and Technology, 37(45), 455107. https://doi.org/10.1088/1361-6501/aeb3a0

Vancouver

Zhang X, Gao S, Huang X, Feng P, Chu J. TF-Former: a concentration regression model for toxic and harmful mixed gases based on time-frequency analysis. Measurement Science and Technology. 2026;37(45):455107. doi:10.1088/1361-6501/aeb3a0

BibTeX
@article{Zhang2026,
  author = {Zhang, Xinyu and Gao, Songqi and Huang, Xiaoran and Feng, Peter and Chu, Jin},
  title = {TF-Former: a concentration regression model for toxic and harmful mixed gases based on time-frequency analysis},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {45},
  pages = {455107},
  doi = {10.1088/1361-6501/aeb3a0}
}
Kostenlos starten →