Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 12.08.2026. Verfasst von Kourosh Kalayeh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, MI, United States of America. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIDDK NIH HHS, National Institute of Diabetes and Digestive and Kidney Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Many experimental and clinical measurements require simultaneous acquisition from independent instruments that do not share a clock. We describe a device that enables such pairings via event-based synchronization: an electrical trigger from one instrument drives an Arduino-controlled stepper actuator that produces a brief mechanical event at a location sensed by the other instrument, leaving a fiducial marker for post-hoc temporal alignment. The motivating application is synchronization of high-resolution manometry (HRM) with transperineal ultrasound for phenotyping stress urinary incontinence. Bench characterization yielded a device latency of 802.5 μ m ± 46.2 μ m (mean ± SD, n = 30 ), of which the electromechanical response of the actuator accounts for ≈ 84 % of the mean latency and the dominant share of the trial-to-trial variation (i.e. the SD of 46.2 μ m ). For the ultrasound–HRM application, the synchronization uncertainty is ≈ 6 ms ( n = 30 markers), set by the HRM rather than the device, whose intrinsic jitter contributes negligibly. The approach generalizes to instrument pairings in which one instrument provides a stable electrical trigger with a known relation to its recording timeline and the other is a mechanically-sensitive receiver of adequate bandwidth, provided the marker does not contaminate the signal of interest.

Schlagwörter

Stichwörter der Autor:innen

event-based synchronizationfiducial markerhigh-resolution manometry (HRM)pelvic floor disordersstress urinary incontinence (SUI)transperineal ultrasound (TPUS)

Autor:innen und Institutionen

  • Department of Radiology, University of Michigan, Ann Arbor, MI, United States of America.
  • Department of Urology, University of Michigan, Ann Arbor, MI, United States of America.
  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, United States of America.
  • Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, United States of America.
  • Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, United States of America.

ORCID-Profile: Kourosh Kalayeh, John O L DeLancey, James A Ashton-Miller, J Brian Fowlkes

Förderung

  • NIDDK NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases

Zitieren

APA

Kalayeh, K., DeLancey, J. O. L., Ashton-Miller, J. A., & Fowlkes, J. B. (2026). Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments. Measurement Science and Technology, 37(32), 325903. https://doi.org/10.1088/1361-6501/ae92a4

Vancouver

Kalayeh K, DeLancey JOL, Ashton-Miller JA, Fowlkes JB. Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments. Measurement Science and Technology. 2026;37(32):325903. doi:10.1088/1361-6501/ae92a4

BibTeX
@article{Kalayeh2026,
  author = {Kalayeh, Kourosh and DeLancey, John O L and Ashton-Miller, James A and Fowlkes, J Brian},
  title = {Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {32},
  pages = {325903},
  doi = {10.1088/1361-6501/ae92a4}
}
Kostenlos starten →