A two-dimensional dynamic calibration method for fast-response pressure-sensitive paint
Measurement Science and Technology · 14.08.2026 · 37 (32) · 325204
DOI: 10.1088/1361-6501/ae920a ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 10.08.2026. Verfasst von Su Xing und 2 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Fast-response pressure‐sensitive paint (fast PSP) is an advanced experimental technique which provides full‐field time-resolved surface pressure data. The paint’s dynamic response is essential for accurate reconstruction of high-frequency pressure fluctuation. However, conventional single‐point or spatially averaged dynamic calibration methods neglect the spatial variation of the paint’s dynamic response and may lead to pressure reconstruction errors. This work proposes a two-dimensional (2D) dynamic calibration method for fast PSP using an acoustic resonance cavity, which is excited at selected resonance frequencies to generate acoustic pressure fields from 606 Hz to 6 Hz. The spatially varying pressure amplitude across the surface leads to highly non-uniform signal-to-noise ratio (SNR) for fast PSP, posing challenge for the robust extraction of 2D dynamic response. To address this issue, the phase delay (instead of magnitude attenuation) of each pixel under different excitation frequency is extracted via cross power spectral density (CPSD) or dynamic mode decomposition (DMD), before it is fitted by a first-order model to get the pixel-wise cut-off frequency of the PSP. Both CPSD and DMD based method recover consistent cut-off frequency distributions, while DMD provides better repeatability by exploiting spatial coherence and filtering uncorrelated noise. To validate the 2D dynamic calibration results, a series of pressure signals acquired from both a pressure sensor and PSP, with and without dynamic correction, are compared. Dynamic correction reduces the root mean square error with respect to the validation sensor by 47.7% using a spatially averaged cut-off frequency and by 55.9% using a pixel-by-pixel correction. These results demonstrate that the proposed method enables robust 2D characterization of PSP dynamic response and provides a basis for uncertainty assessment in unsteady PSP measurements.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xing, S., Liu, Y., & Peng, D. (2026). A two-dimensional dynamic calibration method for fast-response pressure-sensitive paint. Measurement Science and Technology, 37(32), 325204. https://doi.org/10.1088/1361-6501/ae920a
Vancouver
Xing S, Liu Y, Peng D. A two-dimensional dynamic calibration method for fast-response pressure-sensitive paint. Measurement Science and Technology. 2026;37(32):325204. doi:10.1088/1361-6501/ae920a
BibTeX
@article{Xing2026,
author = {Xing, Su and Liu, Yingzheng and Peng, Di},
title = {A two-dimensional dynamic calibration method for fast-response pressure-sensitive paint},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {32},
pages = {325204},
doi = {10.1088/1361-6501/ae920a}
}