Stewart platform-based monocular vision calibration and correction method for low-frequency multi-axial vibration sensors

Xinxu Liu, Chenguang Cai, Zhihua Liu, Ming Yang, Deguang Wang

Measurement Science and Technology · 24.07.2026 · 37 (29) · 295007

DOI: 10.1088/1361-6501/ae8a73 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 27.07.2026. Verfasst von Xinxu Liu und 4 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key R&D Program of China, Guizhou Provincial Key Technology R&D Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low-frequency vibration sensors are widely applied in the key fields of intelligent assembly manufacturing, inertial navigation, and robot pose estimation. They must be calibrated within a specific calibration cycle to ensure the accuracy and reliability of their measurement data. The Stewart platform is capable of providing spatial excitation for the sensors in multiple motion directions simultaneously, which can significantly improve the calibration efficiency while reducing the installation errors that cause additional uncertainty. However, due to the mechanical properties of the Stewart platform and the load of the sensors, the provided excitation direction and the working surface motion direction inevitably involve a bending angle, which causes an extra excitation acceleration. To reduce the additional excitation influence on the calibration accuracy, a new monocular vision calibration and correction method based on the Stewart platform is proposed for the sensors. This method utilizes a laser projector to achieve physical decoupling measurement of complex spatial motion and accurately measure the input excitation of the sensors by processing static and dynamic laser spot images. Thereafter, a sensitivity correction formula is established by eliminating the influence of the bending angle. The experimental results demonstrate that, after the bending correction, the proposed method improves the accuracy by about 10%. The maximum relative deviation with traditional laser interferometry with a single shaker and the monocular vision method with a two-axis shaker were 2.9% and 0.5% in the 0.16–2 Hz range. Meanwhile, the proposed method also achieved considerable repeatability.

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Program of China
  • Guizhou Provincial Key Technology R&D Program

Zitieren

APA

Liu, X., Cai, C., Liu, Z., Yang, M., & Wang, D. (2026). Stewart platform-based monocular vision calibration and correction method for low-frequency multi-axial vibration sensors. Measurement Science and Technology, 37(29), 295007. https://doi.org/10.1088/1361-6501/ae8a73

Vancouver

Liu X, Cai C, Liu Z, Yang M, Wang D. Stewart platform-based monocular vision calibration and correction method for low-frequency multi-axial vibration sensors. Measurement Science and Technology. 2026;37(29):295007. doi:10.1088/1361-6501/ae8a73

BibTeX
@article{Liu2026,
  author = {Liu, Xinxu and Cai, Chenguang and Liu, Zhihua and Yang, Ming and Wang, Deguang},
  title = {Stewart platform-based monocular vision calibration and correction method for low-frequency multi-axial vibration sensors},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {29},
  pages = {295007},
  doi = {10.1088/1361-6501/ae8a73}
}
Kostenlos starten →