EUVIMEDEUVIMED entdecken
Crossref

Physics-informed digital twin for adaptive smart anemometry: overcoming the bandwidth–sensitivity barrier

Malik I Al-Amayreh, Ahmad Alamayreh

Measurement Science and Technology · 24.07.2026 · 37 (29) · 295102

DOI: 10.1088/1361-6501/ae8874 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 20.07.2026. Verfasst von Malik I Al-Amayreh und 1 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hot-wire anemometry is fundamentally constrained by an inverse physical relationship between static sensitivity and dynamic bandwidth, creating an inherent trade-off between measurement precision and response speed. Conventional single-mode architectures cannot achieve optimal performance across the full velocity envelope: constant power (CP) operation offers superior sensitivity but becomes dynamically unstable at low flow velocities due to excessive thermal inertia, while the constant temperature difference (CTD) mode guarantees stability under weak convective cooling yet suffers from severely degraded resolution at high velocities, where elevated electronic noise floors dominate. To address these limitations, this work introduces a physics-informed digital twin control framework that enables adaptive mode switching designed for real-time minimization of the velocity resolution limit ( δ U min ) for hot-wire sensors. The proposed control architecture employs a unified utility function that simultaneously maximizes the signal-to-noise ratio (SNR) while enforcing a bandwidth-penalized dynamic fidelity constraint. For a defined target bandwidth of 1000 Hz, the controller defaults to CTD mode at low velocities ( U < 4.3 m s −1 ) to ensure stability when convective heat transfer cannot sufficiently counteract thermal inertia. As velocity increases, the system autonomously transitions to CP mode once the intrinsic thermal time constant satisfies the required bandwidth, safely unlocking up to three orders of magnitude of precision improvement relative to a conventional, stability-locked CTD baseline. The steady-state physics engine is validated against experimental power consumption benchmarks ( R 2 = 0.95 , MAPE = 2.01 % ), accurately resolving complex substrate heat leakage without empirical curve-fitting. The resulting hybrid architecture achieves a resolution gain factor of > 2700 relative to conventional methods, offering a scalable, geometry-invariant solution for next-generation aerodynamic and fluid-mechanics measurement systems.

Zitieren

APA

Al-Amayreh, M. I., & Alamayreh, A. (2026). Physics-informed digital twin for adaptive smart anemometry: overcoming the bandwidth–sensitivity barrier. Measurement Science and Technology, 37(29), 295102. https://doi.org/10.1088/1361-6501/ae8874

Vancouver

Al-Amayreh MI, Alamayreh A. Physics-informed digital twin for adaptive smart anemometry: overcoming the bandwidth–sensitivity barrier. Measurement Science and Technology. 2026;37(29):295102. doi:10.1088/1361-6501/ae8874

BibTeX
@article{AlAmayreh2026,
  author = {Al-Amayreh, Malik I and Alamayreh, Ahmad},
  title = {Physics-informed digital twin for adaptive smart anemometry: overcoming the bandwidth–sensitivity barrier},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {29},
  pages = {295102},
  doi = {10.1088/1361-6501/ae8874}
}
Kostenlos starten →