EUVIMEDEUVIMED entdecken
Crossref

Design, modeling and testing of a decoupling 2-DOF PZT micro-positioning platform

Ran Cao, Yali Yi, Xukang Zhou, Xueyan Han, Xiangcheng Chu, Herong Jin

Measurement Science and Technology · 17.07.2026 · 37 (28) · 286003

DOI: 10.1088/1361-6501/ae87b9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 17.07.2026. Verfasst von Ran Cao und 5 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: State Key Laboratory of New Ceramic Materials Tsinghua University, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aiming at the issue of coupled displacement in the parallel compliant mechanism of the two-degree-of-freedom (2-DOF) piezoelectric micro-positioning platform, this paper performs a rigid-body equivalence of the 2-PP type compliant mechanism and conducts kinematic analysis to reveal the mechanism of coupling generation. A ‘suitable constraint branch chain’ is introduced to eliminate the coupling between orthogonal chains, and a quasi-symmetric micro-positioning platform configuration with decoupling function is proposed. Based on the rigid-body replacement method, the compliant mechanism is designed to ensure that the output component undergoes pure translation without rotation, thereby achieving decoupling. A stiffness model of the compliant micro-positioning platform is established to clarify the dimensional design principles of the mechanism. A static model is developed using Castigliano’s theorem and the pseudo-rigid-body model to identify the factors influencing. Finite element simulation and experimental verification are conducted. The results show that the deformation difference between the constrained branched chains of the designed positioning platform is 4.3%, the deviation between the theoretical and simulated amplification ratios is 2.69%, the workspace is 63.5 μm × 54.0 μm, and the coupling rates are 0.47% and 0.74%, respectively, verifying the correctness of the decoupling method and the theoretical model. This research provides guidance for the decoupling design of 2-DOF positioning platforms.

Förderung

  • State Key Laboratory of New Ceramic Materials Tsinghua University
  • National Natural Science Foundation of China

Zitieren

APA

Cao, R., Yi, Y., Zhou, X., Han, X., Chu, X., & Jin, H. (2026). Design, modeling and testing of a decoupling 2-DOF PZT micro-positioning platform. Measurement Science and Technology, 37(28), 286003. https://doi.org/10.1088/1361-6501/ae87b9

Vancouver

Cao R, Yi Y, Zhou X, Han X, Chu X, Jin H. Design, modeling and testing of a decoupling 2-DOF PZT micro-positioning platform. Measurement Science and Technology. 2026;37(28):286003. doi:10.1088/1361-6501/ae87b9

BibTeX
@article{Cao2026,
  author = {Cao, Ran and Yi, Yali and Zhou, Xukang and Han, Xueyan and Chu, Xiangcheng and Jin, Herong},
  title = {Design, modeling and testing of a decoupling 2-DOF PZT micro-positioning platform},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {28},
  pages = {286003},
  doi = {10.1088/1361-6501/ae87b9}
}