EUVIMEDEUVIMED entdecken
Crossref

Sample-weighted prototypical network with EMD distance: a few-shot fault diagnosis approach for wind turbine generators

Likui Qiao, Wenhui Li

Measurement Science and Technology · 26.06.2026 · 37 (26) · 266109

DOI: 10.1088/1361-6501/ae7fa6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 30.06.2026. Verfasst von Likui Qiao und 1 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the challenges of limited fault data and the difficulty of few-shot learning in real-world wind turbine operations, this study proposes a convolutional standard Transformer encoding framework based on a prototypical network, termed convolution-enhanced Transformer encoder (CNTE)-PN. Adopting a meta-learning paradigm, the method constructs multiple N -way K -shot tasks from limited samples to enhance the model’s generalization capability. To efficiently extract discriminative features from multivariate time series signals of wind turbines, a feature extraction module named CNTE is designed. In this module, one-dimensional convolution is employed to capture local temporal patterns, while the Transformer encoder is used to model global dependencies, enabling a unified representation that integrates both local and global features. Additionally, a sample weighting strategy based on intra-class variation is introduced to dynamically generate class prototypes. The Earth mover’s distance, derived from optimal transport theory, is applied to quantify the distributional discrepancy between query samples and prototypes, thereby improving diagnostic accuracy under few-shot conditions. To verify the effectiveness of the proposed method, this study first constructs a multivariate dynamic response dataset under parameter perturbations of a 5 MW wind turbine based on the OpenFAST platform, and then conducts comparative experiments and ablation analyses. On this basis, real wind farm SCADA data are further introduced for experimental validation. The results show that CNTE-PN achieves superior performance in terms of diagnostic accuracy, robustness, and feature representation capability, demonstrating its application potential for multivariate operating condition identification under few-shot scenarios.

Zitieren

APA

Qiao, L., & Li, W. (2026). Sample-weighted prototypical network with EMD distance: a few-shot fault diagnosis approach for wind turbine generators. Measurement Science and Technology, 37(26), 266109. https://doi.org/10.1088/1361-6501/ae7fa6

Vancouver

Qiao L, Li W. Sample-weighted prototypical network with EMD distance: a few-shot fault diagnosis approach for wind turbine generators. Measurement Science and Technology. 2026;37(26):266109. doi:10.1088/1361-6501/ae7fa6

BibTeX
@article{Qiao2026,
  author = {Qiao, Likui and Li, Wenhui},
  title = {Sample-weighted prototypical network with EMD distance: a few-shot fault diagnosis approach for wind turbine generators},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {26},
  pages = {266109},
  doi = {10.1088/1361-6501/ae7fa6}
}
Kostenlos starten →