EUVIMEDEUVIMED entdecken
Crossref

Experimental and numerical investigation of ultrasonic-based gas detection and leak prevention strategies in semiconductor gas cabinets

Seonmin Lee, Hee-Eun Lee, Chang-hyun Shin, Chankyu Kang

Measurement Science and Technology · 03.07.2026 · 37 (27) · 275102

DOI: 10.1088/1361-6501/ae7ea1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 01.07.2026. Verfasst von Seonmin Lee und 3 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Gefördert von: National Institute of Chemical Safety.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gas cabinets are vital for safely handling high-pressure hazardous gases in semiconductor manufacturing, where rapid leak detection is essential to prevent safety incidents and production disruptions. Despite widespread use, conventional electrochemical sensors for gas leak detection respond slowly (30–60 s T90) and are limited by gas specificity, leaving a significant gap in universally effective and rapid detection for high-pressure releases. This study systematically investigates gas leakage characteristics in semiconductor gas cabinets, employing both full-scale experiments and computational fluid dynamics (CFD) simulations to understand how gas pressure, leakage angle, and leak position influence hazardous gas dispersion. Flow measurements and high-speed imaging identified the most significant leakage at the cabinet bottom, 135° angle, and 0.7 MPa pressure. CFD results validated against experimental measurements showed deviations within ±0.2 m s −1 . Simulations with silane and ammonia revealed that ammonia, due to its lower molecular weight and higher diffusion coefficient, dispersed more rapidly than silane. In argon gas experiments, the ultrasonic sensor consistently detected leaks within 0.4 s under all conditions; in contrast, the electrochemical sensor failed to respond at low pressures (0.15 MPa). Activation of the ultrasonic-linked interlock system effectively confined gas dispersion to within 1.1 m with maximum external concentrations of 0.012 ppm, compared to 70 000 ppm when using electrochemical sensors alone (CFD-validated). This work establishes validated performance benchmarks for ultrasonic-interlock systems, demonstrating prompt, reliable leak detection and containment that meets advanced safety management requirements in semiconductor facilities.

Förderung

  • National Institute of Chemical Safety

Zitieren

APA

Lee, S., Lee, H., Shin, C., & Kang, C. (2026). Experimental and numerical investigation of ultrasonic-based gas detection and leak prevention strategies in semiconductor gas cabinets. Measurement Science and Technology, 37(27), 275102. https://doi.org/10.1088/1361-6501/ae7ea1

Vancouver

Lee S, Lee H, Shin C, Kang C. Experimental and numerical investigation of ultrasonic-based gas detection and leak prevention strategies in semiconductor gas cabinets. Measurement Science and Technology. 2026;37(27):275102. doi:10.1088/1361-6501/ae7ea1

BibTeX
@article{Lee2026,
  author = {Lee, Seonmin and Lee, Hee-Eun and Shin, Chang-hyun and Kang, Chankyu},
  title = {Experimental and numerical investigation of ultrasonic-based gas detection and leak prevention strategies in semiconductor gas cabinets},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {27},
  pages = {275102},
  doi = {10.1088/1361-6501/ae7ea1}
}