EUVIMEDEUVIMED entdecken
Crossref

Tunable diode laser absorption spectroscopy measurement of water vapor in high-temperature gases

Jie Gao, Jianyu Chao, Tielou Liu, Yi Jin, Dong He, Chao Zhai, Jisen Yuan, Ting Si

Measurement Science and Technology · 12.06.2026 · 37 (24) · 245201

DOI: 10.1088/1361-6501/ae7593 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 15.06.2026. Verfasst von Jie Gao und 7 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate temperature and species measurements in high-enthalpy environments depend on validated high-temperature spectroscopic parameters; however, widely used parameters from HITRAN 2024 and HITEMP 2010 lack experimentally validated parameters for key near-infrared H₂O transitions above ∼1400 K. In this study, a complete calibration measurement framework for tunable diode laser absorption spectroscopy (TDLAS) was developed using a kinetics shock tube. High-temperature H₂O was generated in situ through shock-induced combustion of the N 2 -diluted H₂/O₂ mixture to eliminate adsorption losses on stainless-steel surfaces, enabling stable test conditions over 1610–2940 K and 1–3 atm. Three widely used transitions centered at 7185.60, 6806.03, and 7444.35/37 cm −1 were measured for line strength and N 2 -perturbed collisional broadening coefficients, supported by a W-shaped multi-pass optical path that enhances absorbance and reduces Voigt-fit residuals to below 3%. The calibrated parameters exhibited uncertainties within 5.83%, effectively extending and correcting the existing spectroscopic parameters within the applicable high-temperature range. To validate the calibrated parameters, a scanned-wavelength modulation method combined with a newly developed two-line intersection inversion algorithm was applied to measurements behind reflected shocks, retrieving temperature and H₂O mole fraction through the intersection of simulated 2 f /1 f contour curves. Validation experiments demonstrated deviations within 3.0% for both temperature and concentration, confirming that the proposed calibration–measurement framework enables accurate and robust near-infrared TDLAS diagnostics in high-enthalpy flow fields.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Gao, J., Chao, J., Liu, T., Jin, Y., He, D., Zhai, C., Yuan, J., & Si, T. (2026). Tunable diode laser absorption spectroscopy measurement of water vapor in high-temperature gases. Measurement Science and Technology, 37(24), 245201. https://doi.org/10.1088/1361-6501/ae7593

Vancouver

Gao J, Chao J, Liu T, Jin Y, He D, Zhai C, et al. Tunable diode laser absorption spectroscopy measurement of water vapor in high-temperature gases. Measurement Science and Technology. 2026;37(24):245201. doi:10.1088/1361-6501/ae7593

BibTeX
@article{Gao2026,
  author = {Gao, Jie and Chao, Jianyu and Liu, Tielou and Jin, Yi and He, Dong and Zhai, Chao and Yuan, Jisen and Si, Ting},
  title = {Tunable diode laser absorption spectroscopy measurement of water vapor in high-temperature gases},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {24},
  pages = {245201},
  doi = {10.1088/1361-6501/ae7593}
}
Kostenlos starten →