Experimental study on ion adsorption–desorption in resuspended sediments: critical salinity threshold and grain size effects on salinity variations
Measurement Science and Technology · 22.05.2026 · 37 (21) · 215803
DOI: 10.1088/1361-6501/ae6de8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 27.05.2026. Verfasst von Takahisa Tokunaga und 1 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Gefördert von: the JSPS Grant-in-Aid for Scientific Research.
Abstract (Originalsprache)
This study investigates how natural suspended sediments modify conductivity-based salinity measurements and establishes a metrological framework to quantify these effects in turbid coastal waters. Laboratory experiments were conducted using ion-adsorbed sediments collected from Ariake Bay, Japan, over a wide range of initial salinities (0.02–32.93 PSU) and suspended-solid concentrations. Salinity was measured with a conductivity–temperature–depth profiler (CTD), and the coefficient of salinity change ( α , l g −1 ) defined as the apparent salinity variation per unit suspended-solid concentration was derived from repeated measurements and analyzed as a function of salinity and mud content. The results provide the first experimental evidence that naturally ion-adsorbed sediments can induce a bidirectional response in conductivity-based salinity sensors. Specifically, α became positive at low salinities, indicating an apparent salinity increase caused by ion desorption from sediment surfaces, whereas α became negative at high salinities owing to ion adsorption and volume-exclusion effects. A critical salinity threshold of 16.64 PSU was identified as the transition between desorption-dominant and adsorption-dominant regimes for the sediment used in this study. Experiments with controlled mud fractions showed that the magnitude of α and its salinity-dependence coefficient ( β ) increased systematically with finer particle content, highlighting the role of specific surface area and mineralogy. Measurement uncertainty of α was evaluated following the ISO GUM framework, yielding a combined standard uncertainty of 9.0 × 10 − ⁴ l g −1 and an expanded uncertainty of ±0.0018 l g −1 ( k = 2). These findings provide a traceable basis for correcting sediment-induced salinity bias and for developing calibration and compensation algorithms for CTD sensors and related conductivity-based instruments operating in turbid, variable-salinity environments.
Förderung
- the JSPS Grant-in-Aid for Scientific Research
Zitieren
APA
Tokunaga, T., & Matsuyama, Y. (2026). Experimental study on ion adsorption–desorption in resuspended sediments: critical salinity threshold and grain size effects on salinity variations. Measurement Science and Technology, 37(21), 215803. https://doi.org/10.1088/1361-6501/ae6de8
Vancouver
Tokunaga T, Matsuyama Y. Experimental study on ion adsorption–desorption in resuspended sediments: critical salinity threshold and grain size effects on salinity variations. Measurement Science and Technology. 2026;37(21):215803. doi:10.1088/1361-6501/ae6de8
BibTeX
@article{Tokunaga2026,
author = {Tokunaga, Takahisa and Matsuyama, Yukihiko},
title = {Experimental study on ion adsorption–desorption in resuspended sediments: critical salinity threshold and grain size effects on salinity variations},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {21},
pages = {215803},
doi = {10.1088/1361-6501/ae6de8}
}
EUVIMED