A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms
Measurement Science and Technology · 05.06.2026 · 37 (23) · 235001
DOI: 10.1088/1361-6501/ae6d1e ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 08.06.2026. Verfasst von Yanbin Li und 7 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Active magnetic compensation (AMC) technology contributes to the realization of an extremely weak magnetic environment in magnetic shielding rooms (MSR), which is of great significance for measuring biomagnetic signal using an optically pumped magnetometer (OPM) sensor. However, sensor delay degrades the stability of the AMC system, while random magnetic field disturbances impair control accuracy. An active disturbance rejection control method combined with filtered Smith predictor (ADRC-FSP) is proposed to effectively compensate for sensor delay while suppressing random magnetic field disturbances. First, the structure of the AMC system is analyzed, and a mathematical model is established. Then, considering the action path of random disturbances, an ADRC-FSP is designed. Finally, simulations and experiments verify the effectiveness of proposed method, demonstrating improved system stability and a 34.9% increase in compensation accuracy. It has an important contribution to the measurement of biomagnetic signals.
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
Zitieren
APA
Li, Y., Wang, H., Yang, Z., Zhang, H., Zheng, S., Li, H., Cui, P., & Liu, X. (2026). A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms. Measurement Science and Technology, 37(23), 235001. https://doi.org/10.1088/1361-6501/ae6d1e
Vancouver
Li Y, Wang H, Yang Z, Zhang H, Zheng S, Li H, et al. A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms. Measurement Science and Technology. 2026;37(23):235001. doi:10.1088/1361-6501/ae6d1e
BibTeX
@article{Li2026,
author = {Li, Yanbin and Wang, Haoan and Yang, Zhouqiang and Zhang, Haifeng and Zheng, Shiqiang and Li, Haitao and Cui, Peiling and Liu, Ximing},
title = {A method for improving the stability and accuracy of active magnetic compensation system for magnetic shielding rooms},
journal = {Measurement Science and Technology},
year = {2026},
volume = {37},
number = {23},
pages = {235001},
doi = {10.1088/1361-6501/ae6d1e}
}
EUVIMED