EUVIMEDEUVIMED entdecken
Crossref

Reconstruction of temperature field in background oriented schlieren using hybrid variational optical flow algorithm

Hu Li, Lanlan Shen, Haidong Zhu

Measurement Science and Technology · 17.04.2026 · 37 (16) · 165301

DOI: 10.1088/1361-6501/ae5df6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 22.04.2026. Verfasst von Hu Li und 2 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Guilin Institute of Information Technology, Guangxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background oriented schlieren (BOS) is an important non-invasive temperature measurement technology. The fidelity of temperature field reconstruction in BOS is critically dependent on the accuracy of the displacement estimation. At present, the variational optical flow algorithm has been successfully applied to the study of temperature field measurement, which mainly depends on the assumption of constant brightness. However, in the actual BOS experiment, the fuzzy defocusing effect of vibration and uneven illumination and volume refraction makes the constant brightness assumption not suitable for BOS. In this study, a new hybrid variational optical flow method circulant matrix and gradient-constancy based optical flow (CM-GCOF) is proposed. The range and accuracy of the rough calculation displacement field are improved by using the cyclic matrix cross-correlation algorithm and the Gaussian radial basis function interpolation, and the displacement refinement is carried out by combining the improved optical flow algorithm based on the gradient constant assumption. The method was tested on the BOS images of axisymmetric flame numerical simulation with different brightness modes and the experimental images of heat flow field above methane/air laminar premixed flame, and compared with the classical variational optical flow algorithm and the traditional hybrid cross-correlation optical flow method. The experimental results show that the proposed CM-GCOF method has high accuracy and strong robustness for synthetic BOS images with different brightness changes. At the same time, the average relative error between the reconstructed temperature value and the mean value of thermocouple multiple temperature measurements is 2.79%, indicating that the method can accurately reconstruct the temperature field. Therefore, the proposed CM-GCOF method is more suitable for real BOS experiments.

Förderung

  • Guilin Institute of Information Technology
  • Guangxi Province

Zitieren

APA

Li, H., Shen, L., & Zhu, H. (2026). Reconstruction of temperature field in background oriented schlieren using hybrid variational optical flow algorithm. Measurement Science and Technology, 37(16), 165301. https://doi.org/10.1088/1361-6501/ae5df6

Vancouver

Li H, Shen L, Zhu H. Reconstruction of temperature field in background oriented schlieren using hybrid variational optical flow algorithm. Measurement Science and Technology. 2026;37(16):165301. doi:10.1088/1361-6501/ae5df6

BibTeX
@article{Li2026,
  author = {Li, Hu and Shen, Lanlan and Zhu, Haidong},
  title = {Reconstruction of temperature field in background oriented schlieren using hybrid variational optical flow algorithm},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {16},
  pages = {165301},
  doi = {10.1088/1361-6501/ae5df6}
}
Kostenlos starten →