EUVIMEDEUVIMED entdecken
Crossref

An inclination angle and wind deflection angle sensing method based on triboelectric nanogenerator for transmission line fault monitoring

Changxin Liu, Peihan Huang, Yong Cui, Yang Liu, Ke Yang, Fang Liu, Xing Feng, Mingyu Lu

Measurement Science and Technology · 20.03.2026 · 37 (11) · 115103

DOI: 10.1088/1361-6501/ae4e04 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 23.03.2026. Verfasst von Changxin Liu und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key R&D Project, Ministry of Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Under complex meteorological conditions, the wind deflection angle and inclination angle of transmission lines are prone to drastic changes. It can lead to flashover or line breakage. Therefore, it is important to monitor the wind deflection angle and inclination angle of transmission lines. A dual-dimensional sensing method is proposed in this study. This approach is based on triboelectric nanogenerator (TENG) and is designed to measure the inclination angle and wind deflection angle of transmission lines. A theoretical model for dual-dimensional perception is established. Additionally, a dual-dimensional angle sensing unit (DA-SU) is innovatively designed. The DA-SU contains an inclination angle-sensitive TENG (IS-TENG) and a wind deflection angle-sensitive TENG (WS-TENG) within its structure. An experiment system is set up. Experiments are carried out to validate DA-SU’s perception function and test its performance. The experiment results demonstrate that a clear correspondence exists between the sum of the peak output voltages of the IS-TENG and the inclination angle values. The perception error rate is kept below 3.2%. The peak output voltage of the WS-TENG is positively correlated with the magnitude of the wind deflection angle. After undergoing 300 000 cycles of testing, the output voltage of the WS-TENG exhibits no significant distortion. This demonstrates that the DA-SU has a good capability to perceive the wind deflection angle and inclination angle of transmission lines. When applied to transmission line fault detection, it can provide strong guarantees for the stability and safety of the power system.

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Project, Ministry of Science and Technology

Zitieren

APA

Liu, C., Huang, P., Cui, Y., Liu, Y., Yang, K., Liu, F., Feng, X., & Lu, M. (2026). An inclination angle and wind deflection angle sensing method based on triboelectric nanogenerator for transmission line fault monitoring. Measurement Science and Technology, 37(11), 115103. https://doi.org/10.1088/1361-6501/ae4e04

Vancouver

Liu C, Huang P, Cui Y, Liu Y, Yang K, Liu F, et al. An inclination angle and wind deflection angle sensing method based on triboelectric nanogenerator for transmission line fault monitoring. Measurement Science and Technology. 2026;37(11):115103. doi:10.1088/1361-6501/ae4e04

BibTeX
@article{Liu2026,
  author = {Liu, Changxin and Huang, Peihan and Cui, Yong and Liu, Yang and Yang, Ke and Liu, Fang and Feng, Xing and Lu, Mingyu},
  title = {An inclination angle and wind deflection angle sensing method based on triboelectric nanogenerator for transmission line fault monitoring},
  journal = {Measurement Science and Technology},
  year = {2026},
  volume = {37},
  number = {11},
  pages = {115103},
  doi = {10.1088/1361-6501/ae4e04}
}
Kostenlos starten →