EUVIMEDEUVIMED entdecken
Crossref

Conjugate differential self-calibration of a large-scale two-dimensional variable-line-spacing grating for an absolute optical encoder using a Fizeau phase-shifting interferometer

Chenguang Yin, Xin Xiong, Ryo Sato, Hiraku Matsukuma, Hideaki Tamiya, Wei Gao

Measurement Science and Technology · 31.07.2025 · 36 (7) · 075023

DOI: 10.1088/1361-6501/adee34 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 22.07.2025. Verfasst von Chenguang Yin und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Japan Science and Technology Agency, Japan Society for the Promotion of Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, a conjugate differential self-calibration method is proposed for fast evaluation of pitch variation in two-dimensional (2D) large-scale variable-line-spacing (VLS) gratings using a Fizeau phase-shifting interferometer. In the novel method, the original and two orthogonally conjugate positions are established through small lateral translations for measuring differential diffracted wavefronts from the target VLS grating. Arithmetic operations on these wavefronts at the three positions are employed to mitigate the influence of noise and tilt errors, elevating the accuracy of retrieving VLS parameters that characterize the pitch variation. Simulations were conducted considering different conditions, and experiments were performed using a Fizeau phase-shifting interferometer to evaluate the VLS parameters of a large-scale 2D VLS grating. The obtained VLS parameters showed strong consistency with those derived from the interferometric stitching measurement. Additionally, a comparison was performed between the reconstructed accumulative errors based on the VLS parameters retrieved by the proposed method and the reading errors of an absolute encoder using the VLS grating, showing the error difference within ±18 nm in the X -direction and ±35 nm in the Y -direction across a 100 mm scanning range, respectively.

Förderung

  • Japan Science and Technology Agency
  • Japan Society for the Promotion of Science

Zitieren

APA

Yin, C., Xiong, X., Sato, R., Matsukuma, H., Tamiya, H., & Gao, W. (2025). Conjugate differential self-calibration of a large-scale two-dimensional variable-line-spacing grating for an absolute optical encoder using a Fizeau phase-shifting interferometer. Measurement Science and Technology, 36(7), 075023. https://doi.org/10.1088/1361-6501/adee34

Vancouver

Yin C, Xiong X, Sato R, Matsukuma H, Tamiya H, Gao W. Conjugate differential self-calibration of a large-scale two-dimensional variable-line-spacing grating for an absolute optical encoder using a Fizeau phase-shifting interferometer. Measurement Science and Technology. 2025;36(7):075023. doi:10.1088/1361-6501/adee34

BibTeX
@article{Yin2025,
  author = {Yin, Chenguang and Xiong, Xin and Sato, Ryo and Matsukuma, Hiraku and Tamiya, Hideaki and Gao, Wei},
  title = {Conjugate differential self-calibration of a large-scale two-dimensional variable-line-spacing grating for an absolute optical encoder using a Fizeau phase-shifting interferometer},
  journal = {Measurement Science and Technology},
  year = {2025},
  volume = {36},
  number = {7},
  pages = {075023},
  doi = {10.1088/1361-6501/adee34}
}