A novel strategy for fault location, isolation, and service restoration in active distribution networks

Yizhe Chen, Yifan Gao, Xianchao Chen, Chao Wang, Heng Chen, Jinghua Wang

Measurement Science and Technology · 30.06.2025 · 36 (6) · 066201

DOI: 10.1088/1361-6501/add6be ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 19.05.2025. Verfasst von Yizhe Chen und 5 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Science and Technology Project of China Southern Power Grid Co., Ltd..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

When a fault arises in an active distribution network, both the grid upstream of the fault point and the distributed generation (DG) downstream of the fault point contribute short-circuit currents, posing challenges for existing centralized feeder automation (FA) technologies in accurately locating and isolating the fault. Moreover, the radial network structure of the distribution network can lead to power outages for downstream loads when the DG downstream of the fault point ceases operation due to islanding effects. To tackle this issue, this paper introduces a communication-based distributed FA strategy that employs interlocking signals between adjacent switches to pinpoint and isolate faults in active distribution networks, effectively minimizing the scope of fault-induced power outages. Furthermore, to guarantee uninterrupted power supply to the non-fault zones located downstream of the fault point, an inverter control strategy integrating voltage negative feedback control, reactive power negative feedback control, and quasi-synchronization grid-connection control is proposed. This strategy allows for seamless switching between grid-following and grid-forming inverter control modes, enabling adaptive grid-connection/islanding control of DGs. Consequently, non-fault areas downstream of the fault point maintain uninterrupted power supply, significantly enhancing the reliability of power supply in distribution networks. Simulation models have been constructed using MATLAB/Simulink to validate the efficacy of the proposed approach.

Förderung

  • Science and Technology Project of China Southern Power Grid Co., Ltd.

Zitieren

APA

Chen, Y., Gao, Y., Chen, X., Wang, C., Chen, H., & Wang, J. (2025). A novel strategy for fault location, isolation, and service restoration in active distribution networks. Measurement Science and Technology, 36(6), 066201. https://doi.org/10.1088/1361-6501/add6be

Vancouver

Chen Y, Gao Y, Chen X, Wang C, Chen H, Wang J. A novel strategy for fault location, isolation, and service restoration in active distribution networks. Measurement Science and Technology. 2025;36(6):066201. doi:10.1088/1361-6501/add6be

BibTeX
@article{Chen2025,
  author = {Chen, Yizhe and Gao, Yifan and Chen, Xianchao and Wang, Chao and Chen, Heng and Wang, Jinghua},
  title = {A novel strategy for fault location, isolation, and service restoration in active distribution networks},
  journal = {Measurement Science and Technology},
  year = {2025},
  volume = {36},
  number = {6},
  pages = {066201},
  doi = {10.1088/1361-6501/add6be}
}
Kostenlos starten →