Comparison of fiber interferometric sensor with a commercial interferometer for a Kibble balance velocity calibration
Measurement Science and Technology · 01.12.2023 · 34 (12) · 125017
DOI: 10.1088/1361-6501/acf2b7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 30.08.2023. Verfasst von Vitalii Shmagun und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
This article presents a fiber interferometric sensor (FIS) for measuring the velocity amplitude of an oscillatory vibrating object, with a focus on velocity mode measurement in applications using the Kibble balance principle. The sensor uses the range-resolved interferometry method to measure the displacement of the moving object and employs a multi-harmonic sine-fit algorithm to estimate the displacement amplitude and frequency, thereby determining the velocity amplitude. This article provides a comprehensive explanation of the experimental setup and the measurement techniques employed, as well as a detailed analysis of the uncertainty budget, with the performance validation of the FIS benchmarked against a commercial interferometer within a Kibble balance setup. The velocity amplitude of a coil of the Kibble balance, oscillating with an approx. amplitude of 20 μm and a frequency of 0.25 Hz, was measured using the sensor and found to be 31.282 31 μm s −1 with a relative deviation of −1.9 ppm compared to a commercial interferometer. The high performance of the FIS, especially with regard to non-linearity errors, and the small size of the measuring head enable universality of integration into a wide variety of measurement systems, also including the use as general-purpose vibration and displacement sensor.
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Shmagun, V., Vasilyan, S., Rogge, N., Fröhlich, T., & Kissinger, T. (2023). Comparison of fiber interferometric sensor with a commercial interferometer for a Kibble balance velocity calibration. Measurement Science and Technology, 34(12), 125017. https://doi.org/10.1088/1361-6501/acf2b7
Vancouver
Shmagun V, Vasilyan S, Rogge N, Fröhlich T, Kissinger T. Comparison of fiber interferometric sensor with a commercial interferometer for a Kibble balance velocity calibration. Measurement Science and Technology. 2023;34(12):125017. doi:10.1088/1361-6501/acf2b7
BibTeX
@article{Shmagun2023,
author = {Shmagun, Vitalii and Vasilyan, Suren and Rogge, Norbert and Fröhlich, Thomas and Kissinger, Thomas},
title = {Comparison of fiber interferometric sensor with a commercial interferometer for a Kibble balance velocity calibration},
journal = {Measurement Science and Technology},
year = {2023},
volume = {34},
number = {12},
pages = {125017},
doi = {10.1088/1361-6501/acf2b7}
}