EUVIMEDEUVIMED entdecken
Crossref

FDO-Calibr: visual-aided IMU calibration based on frequency-domain optimization

Yunfei Liu, Zhitian Li, Linhui Xiao, Shuaikang Zheng, Pengcheng Cai, Haifeng Zhang, Pengcheng Zheng, Xudong Zou

Measurement Science and Technology · 01.04.2023 · 34 (4) · 045108

DOI: 10.1088/1361-6501/acadfb ↗

Kurz gefasst

Fachartikel in der Zeitschrift Measurement Science and Technology, online erschienen am 23.01.2023. Verfasst von Yunfei Liu und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: the Key Research Program of Frontier Science, CAS.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nowadays, multi-sensor fusion technology is a fundamental prerequisite to achieve highly autonomous robots and robustness. Many studies have been conducted, such as visual–inertial odometry (VIO), integrated navigation, and LiDAR–inertial odometry. Typically, for VIO, gratifying results have been achieved, ascribing to the complementary sensing capabilities of inertial measurement units (IMUs) and cameras. However, this work mainly focuses on the fusion of visual and inertial data, while the IMU error is less considered, especially for low-cost or poorly calibrated microelectromechanical system (MEMS) IMU. Such errors may have a significant effect on the VIO performance. In this study, we compensated for the IMU using camera assistance. The key characteristic of the method is that we optimize the compensation parameters (scale factor) from coarse to fine by combining the time domain with the frequency domain. The proposed method is to use the time-domain and frequency-domain optimization to suppress large noise in the dynamic calibration process of the extremely low-cost sensor platform. The effectiveness of this method is validated through experiments and simulations. The minimal calibration error (0.46%) is commensurate with the advanced work. By feeding the compensated IMU into the VIO algorithm, the localization accuracy is improved by 9% to 15%. This method improves the performance in the VIO algorithm, which is equipped with the low-cost or poorly calibrated MEMS IMU and reduces the hardware and deployment costs of the system.

Förderung

  • the Key Research Program of Frontier Science, CAS

Zitieren

APA

Liu, Y., Li, Z., Xiao, L., Zheng, S., Cai, P., Zhang, H., Zheng, P., & Zou, X. (2023). FDO-Calibr: visual-aided IMU calibration based on frequency-domain optimization. Measurement Science and Technology, 34(4), 045108. https://doi.org/10.1088/1361-6501/acadfb

Vancouver

Liu Y, Li Z, Xiao L, Zheng S, Cai P, Zhang H, et al. FDO-Calibr: visual-aided IMU calibration based on frequency-domain optimization. Measurement Science and Technology. 2023;34(4):045108. doi:10.1088/1361-6501/acadfb

BibTeX
@article{Liu2023,
  author = {Liu, Yunfei and Li, Zhitian and Xiao, Linhui and Zheng, Shuaikang and Cai, Pengcheng and Zhang, Haifeng and Zheng, Pengcheng and Zou, Xudong},
  title = {FDO-Calibr: visual-aided IMU calibration based on frequency-domain optimization},
  journal = {Measurement Science and Technology},
  year = {2023},
  volume = {34},
  number = {4},
  pages = {045108},
  doi = {10.1088/1361-6501/acadfb}
}
Kostenlos starten →